BALLOON ANGIOPLASTY-BRANCH PULMONARY-ARTERY STENOSIS - RESULTS FROM THE VALVULOPLASTY AND ANGIOPLASTY OF CONGENITAL-ANOMALIES REGISTRY

被引:77
作者
KAN, JS
MARVIN, WJ
BASS, JL
MUSTER, AJ
MURPHY, J
机构
[1] UNIV IOWA HOSP & CLIN,IOWA CITY,IA 52242
[2] CHILDRENS MEM HOSP,CHICAGO,IL 60614
[3] UNIV MINNESOTA HOSP & CLIN,MINNEAPOLIS,MN 55455
[4] CHILDRENS HOSP PHILADELPHIA,PHILADELPHIA,PA
关键词
D O I
10.1016/0002-9149(90)91391-I
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Balloon angioplasty for branch pulmonary artery stenosis was reported from 27 institutions to the Valvuloplasty and Angioplasty of Congenital Anomalies Registry. One hundred eighty-two procedures were performed in 156 patients ranging in age from 0.2 to 46.2 years (mean 7.7). Short-term angiographic appearance, hemodynamic results and immediate complications were recorded. Vessel dimension at the site of stenosis increased from 4.5 ± 2.0 (mean ± standard deviation) to 6.8 ± 3.0 mm (p < 0.001) with greater increases in vessel dimension at the site of stenosis if the balloon diameter was >3 X the original dimension of the stenosis. There was no significant benefit related to age or prior surgical intervention. The mean peak systolic pressure gradient was reduced from 49 ± 25 to 37 ± 26 mm Hg (p < 0.001) and pressure proximal to the stenosis decreased from 69 ± 25 to 63 ± 24 mm Hg (p < 0.001). Complications occurred in 21 patients and included vessel rupture and death in 2 patients, vessel perforation or rupture with survival in 3, cardiac arrest and death in 1, paradoxical embolism and death in 1 and low output and death in 1. Balloon angioplasty for branch pulmonary artery stenosis increases vessel dimension at the site of stenosis, reduces systolic pressure gradient and to a minor degree, reduces proximal pressure. Long-term outcome and potential complications are as yet uncertain. © 1990.
引用
收藏
页码:798 / 801
页数:4
相关论文
共 11 条
[1]   CONGENITAL STENOSIS OF PULMONARY ARTERY BRANCHES [J].
BAUM, D ;
ONGLEY, PA ;
KINCAID, OW ;
KHOURY, GH ;
SWAN, HJC .
CIRCULATION, 1964, 29 (05) :680-&
[2]   SUCCESSFUL BALLOON ANGIOPLASTY OF PERIPHERAL PULMONARY STENOSIS IN WILLIAMS SYNDROME [J].
DORSOGNA, L ;
SANDOR, GGS ;
CULHAM, JAG .
AMERICAN HEART JOURNAL, 1987, 114 (03) :647-648
[3]   MORPHOLOGIC CHANGES IN THE PULMONARY-ARTERIES AFTER PERCUTANEOUS BALLOON ANGIOPLASTY FOR PULMONARY ARTERIAL-STENOSIS [J].
EDWARDS, BS ;
LUCAS, RV ;
LOCK, JE ;
EDWARDS, JE .
CIRCULATION, 1985, 71 (02) :195-201
[4]   PULMONARY ARTERY STENOSIS ASSOCIATED WITH DUCTUS ARTERIOSUS FOLLOWING MATERNAL RUBELLA [J].
EMMANOUILIDES, GC ;
CRITTENDEN, IH ;
LINDE, LM .
CIRCULATION, 1964, 29 (04) :514-&
[5]  
GILL CC, 1977, J THORAC CARDIOV SUR, V73, P436
[6]  
HAWORTH SG, 1981, BRIT HEART J, V45, P133
[7]   TRANSVENOUS ANGIOPLASTY OF EXPERIMENTAL BRANCH PULMONARY-ARTERY STENOSIS IN NEWBORN LAMBS [J].
LOCK, JE ;
NIEMI, T ;
EINZIG, S ;
AMPLATZ, K ;
BURKE, B ;
BASS, JL .
CIRCULATION, 1981, 64 (05) :886-893
[8]   BALLOON DILATION ANGIOPLASTY OF HYPOPLASTIC AND STENOTIC PULMONARY-ARTERIES [J].
LOCK, JE ;
CASTANEDAZUNIGA, WR ;
FUHRMAN, BP ;
BASS, JL .
CIRCULATION, 1983, 67 (05) :962-967
[9]  
MCGOON DC, 1964, MED CLIN N AM, V487, P1083
[10]  
RING JC, 1985, J THORAC CARDIOV SUR, V90, P35