AMPEROMETRIC GLUCOSE BIOSENSOR BASED ON AN ELECTROCATALYTICALLY BULK-MODIFIED EPOXY-GRAPHITE BIOCOMPOSITE

被引:39
作者
CESPEDES, F [1 ]
MARTINEZFABREGAS, E [1 ]
ALEGRET, S [1 ]
机构
[1] UNIV AUTONOMA BARCELONA,DEPT QUIM,SENSORS & BIOSENSORS GRP,E-08193 BARCELONA,SPAIN
关键词
AMPEROMETRY; BIOSENSORS; CATALYTIC METHODS; BIOCOMPOSITES; GLUCOSE BIOSENSOR; EPOXY-GRAPHITE BIOCOMPOSITE;
D O I
10.1016/0003-2670(93)80003-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An inexpensive, robust, polishable and easily machinable amperometric glucose transducer was constructed. The biocomposite materials used were graphite, palladium-gold, non-conducting epoxy resin and glucose oxidase. The enzyme retains its bioactivity in the rigid epoxy-graphite matrix. The electrocatalytic oxidation of hydrogen peroxide is enhanced by gold-palladium and it is used as the analytical signal (at 900 mV vs. Ag/AgCl in a pH 7.00 buffered solution with 0.1 M phosphate and 0.1 M KCI). The biosensor exhibits a linear response to glucose in the 0.01-2 mM range and produces steady-state signals within a few seconds (6 s for 95% signal). Simple polishing procedures can be used to generate a fresh bioactive transducer surface.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 10 条
[1]   BIOSENSORS BASED ON CONDUCTING FILLED POLYMER ALL-SOLID-STATE PVC MATRIX MEMBRANE ELECTRODES [J].
ALEGRET, S ;
MARTINEZFABREGAS, E .
BIOSENSORS, 1989, 4 (05) :287-297
[2]   AMPEROMETRIC ENZYMATIC GLUCOSE ELECTRODE BASED ON AN EPOXY GRAPHITE COMPOSITE [J].
CESPEDES, F ;
MARTINEZFABREGAS, E ;
BARTROLI, J ;
ALEGRET, S .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :409-417
[3]   ELIMINATION OF INTERFERENCES IN FLOW-INJECTION AMPEROMETRIC DETERMINATION OF GLUCOSE IN BLOOD-SERUM USING IMMOBILIZED GLUCOSE-OXIDASE [J].
MATUSZEWSKI, W ;
TROJANOWICZ, M ;
LEWENSTAM, A .
ELECTROANALYSIS, 1990, 2 (08) :607-615
[4]   CHEMICALLY MODIFIED CARBON PASTE AND CARBON COMPOSITE ELECTRODES [J].
STARA, V ;
KOPANICA, M .
ELECTROANALYSIS, 1989, 1 (03) :251-256
[5]   MODIFIED ELECTRODES FOR ELECTROCHEMICAL SENSORS [J].
WANG, J .
ELECTROANALYSIS, 1991, 3 (4-5) :255-259
[6]   POLISHABLE AND ROBUST BIOLOGICAL ELECTRODE SURFACES [J].
WANG, J ;
VARUGHESE, K .
ANALYTICAL CHEMISTRY, 1990, 62 (03) :318-320
[7]   RENEWABLE ALCOHOL BIOSENSORS BASED ON ALCOHOL-DEHYDROGENASE NICOTINAMIDE-ADENINE-DINUCLEOTIDE GRAPHITE EPOXY ELECTRODES [J].
WANG, J ;
GONZALEZROMERO, E ;
OZSOZ, M .
ELECTROANALYSIS, 1992, 4 (05) :539-544
[8]   A POLISHABLE AMPEROMETRIC BIOSENSOR FOR BILIRUBIN [J].
WANG, J ;
OZSOZ, M .
ELECTROANALYSIS, 1990, 2 (08) :647-650
[9]   BULK MODIFIED ENZYME ELECTRODES FOR REAGENTLESS DETECTION OF PEROXIDES [J].
WOLLENBERGER, U ;
WANG, J ;
OZSOZ, M ;
GONZALEZROMERO, E ;
SCHELLER, F .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1991, 26 (02) :287-296
[10]  
YANG XR, 1989, MIKROCHIM ACTA, V1, P9