EVALUATION OF THE MULTITEST DEVICE FOR IMMEDIATE HYPERSENSITIVITY SKIN TESTING

被引:38
|
作者
BERKOWITZ, RB [1 ]
TINKELMAN, DG [1 ]
LUTZ, C [1 ]
CRUMMIE, A [1 ]
SMITH, K [1 ]
机构
[1] ATLANTA ALLERGY & IMMUNOL RES FDN,ATLANTA,GA
关键词
MULTITEST; SKIN TESTING; VARIABILITY; REPRODUCIBILITY; STANDARDIZATION; HISTAMINE; ALLERGENS; SITE SPACING;
D O I
10.1016/0091-6749(92)90471-D
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Test-to-test reproducibility, user variability, and the effect of positive reactions on adjacent negative sites were evaluated for the Multi-Test skin testing device. Twenty-five subjects had skin tests with 24 histamine (1 mg/ml), four glycerosaline controls, and four ''dry'' controls on two testings 7 days apart. To assess reproducibility from large and smaller histamine reactions and/or their effect on adjacent negative controls, 10 of the 25 subjects were retested once with the same testing format, but histamine at 10 mg/ml was substituted. To determine whether large allergen reactions affect adjacent negative controls differently than histamine reactions, 24 additional patients were retested on arms and back with negative controls adjacent to allergens to which they had prior 3+ to 4+ skin test reactions. Conclusions from 2688 skin tests on 49 patients are as follows: large (mean >10 mm) histamine reactions reproduced better than smaller (mean <7 mm) responses-coefficients of variation were 12.3 and 21.4 respectively. A 14% user variability occurred when comparing mean wheal sizes from histamine produced by each nurse and 1.2% when comparing their coefficients of variation. Neither small histamine reactions nor large reactions from histamine and allergens affected adjacent negative controls. We conclude that Multi-Test is a highly reliable skin testing technique that provides good reproducibility of results and low user variability.
引用
收藏
页码:979 / 985
页数:7
相关论文
共 50 条
  • [41] Delayed hypersensitivity skin testing
    Yates, AB
    deShazo, RD
    IMMUNOLOGY AND ALLERGY CLINICS OF NORTH AMERICA, 2001, 21 (02) : 383 - +
  • [42] SKIN PRICK TEST RESPONSES TO CODEINE, HISTAMINE, AND RAGWEED UTILIZING THE MULTITEST DEVICE
    LIN, RY
    ERLICH, ER
    DON, PC
    ANNALS OF ALLERGY, 1990, 65 (03): : 222 - 226
  • [43] SUSPECTED OCRELIZUMAB-INDUCED IMMEDIATE HYPERSENSITIVITY: NEGATIVE SKIN TESTING AND DRUG PROVOCATION TEST
    Reddy, K.
    Carrillo-Martin, I.
    Lopez-Chiriboga, A.
    Gonzalez-Estrada, A.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2021, 127 (05) : S74 - S74
  • [44] Skin Testing in the Evaluation and Management of Carboplatin-Related Hypersensitivity Reactions
    Lax, Timothy
    Long, Aidan
    Banerji, Aleena
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE, 2015, 3 (06): : 856 - 862
  • [45] Rituximab Hypersensitivity: Evaluation, Implications of Skin Testing, Potential Mechanisms, and Desensitization
    Wong, Johnson T.
    Banerji, Aleena
    Lax, Timothy P.
    Long, Aidan
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2015, 135 (02) : AB233 - AB233
  • [46] DOSE DEPENDENT WHEAL RESPONSES TO EPICUTANEOUS CODEINE PHOSPHATE - A STUDY OF ALLERGEN, CODEINE AND HISTAMINE SKIN TESTING UTILIZING THE MULTITEST DEVICE
    ERLICH, ER
    LIN, RY
    DON, PC
    CLINICAL RESEARCH, 1989, 37 (02): : A239 - A239
  • [47] Immunologic Evaluation of Immediate Hypersensitivity to Cefaclor
    Yoo, Hye-Soo
    Kim, Seung-Hyun
    Kwon, Hyouk-Soo
    Kim, Tae-Bum
    Nam, Young-Hee
    Ye, Young-Min
    Park, Hae-Sim
    YONSEI MEDICAL JOURNAL, 2014, 55 (06) : 1473 - 1483
  • [48] STUDY IN A FRENCH REFERENCE POPULATION OF CUTANEOUS DELAYED-HYPERSENSITIVITY USING THE IMC MULTITEST DEVICE
    BIRON, G
    ROUMIANTZEFF, M
    AJJAN, N
    RICHARD, C
    TIXIER, G
    SERROU, B
    ANNALES DE L ANESTHESIOLOGIE FRANCAISE, 1981, 22 (03): : 270 - 278
  • [49] Diagnostic evaluation of patients with immediate allergy to penicillins: The role of skin testing
    Torres, MJ
    Leyva, L
    Mayorga, C
    Moya, M
    Gonzalez, L
    Ramano, A
    Blanca, M
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2001, 107 (02) : S3 - S3
  • [50] MEASUREMENT OF DELAYED CUTANEOUS HYPERSENSITIVITY BY THE MULTITEST SYSTEM
    POIROT, P
    DEFAYOLLE, M
    BIRON, G
    ROUMIANTZEFF, M
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 1982, 41 (04): : 175 - 175