EVALUATION OF THE MULTITEST DEVICE FOR IMMEDIATE HYPERSENSITIVITY SKIN TESTING

被引:38
作者
BERKOWITZ, RB [1 ]
TINKELMAN, DG [1 ]
LUTZ, C [1 ]
CRUMMIE, A [1 ]
SMITH, K [1 ]
机构
[1] ATLANTA ALLERGY & IMMUNOL RES FDN,ATLANTA,GA
关键词
MULTITEST; SKIN TESTING; VARIABILITY; REPRODUCIBILITY; STANDARDIZATION; HISTAMINE; ALLERGENS; SITE SPACING;
D O I
10.1016/0091-6749(92)90471-D
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Test-to-test reproducibility, user variability, and the effect of positive reactions on adjacent negative sites were evaluated for the Multi-Test skin testing device. Twenty-five subjects had skin tests with 24 histamine (1 mg/ml), four glycerosaline controls, and four ''dry'' controls on two testings 7 days apart. To assess reproducibility from large and smaller histamine reactions and/or their effect on adjacent negative controls, 10 of the 25 subjects were retested once with the same testing format, but histamine at 10 mg/ml was substituted. To determine whether large allergen reactions affect adjacent negative controls differently than histamine reactions, 24 additional patients were retested on arms and back with negative controls adjacent to allergens to which they had prior 3+ to 4+ skin test reactions. Conclusions from 2688 skin tests on 49 patients are as follows: large (mean >10 mm) histamine reactions reproduced better than smaller (mean <7 mm) responses-coefficients of variation were 12.3 and 21.4 respectively. A 14% user variability occurred when comparing mean wheal sizes from histamine produced by each nurse and 1.2% when comparing their coefficients of variation. Neither small histamine reactions nor large reactions from histamine and allergens affected adjacent negative controls. We conclude that Multi-Test is a highly reliable skin testing technique that provides good reproducibility of results and low user variability.
引用
收藏
页码:979 / 985
页数:7
相关论文
共 16 条
[1]   SOME VARIABLES IN SKIN PRICK TESTING [J].
AAS, K .
ALLERGY, 1980, 35 (03) :250-252
[2]   STANDARDIZATION OF ALLERGEN EXTRACTS WITH APPROPRIATE METHODS - COMBINED USE OF SKIN PRICK TESTING AND RADIO-ALLERGOSORBENT TESTS [J].
AAS, K ;
BACKMAN, A ;
BELIN, L ;
WEEKE, B .
ALLERGY, 1978, 33 (03) :130-137
[3]   A COMPARISON OF 6 EPICUTANEOUS DEVICES IN THE PERFORMANCE OF IMMEDIATE HYPERSENSITIVITY SKIN TESTING [J].
ADINOFF, AD ;
ROSLONIEC, DM ;
MCCALL, LL ;
NELSON, HS .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1989, 84 (02) :168-174
[4]   EVALUATION OF A MULTITEST DEVICE FOR ALLERGY TESTING [J].
BASARAN, M ;
HEIN, EW .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1988, 81 (01) :171-171
[5]  
ENGLER DB, 1991, J ALLERGY CLIN IMMUN, V87, P329
[6]  
GARIBALDI E, 1990, ANN ALLERGY, V65, P481
[7]  
GRATER WC, 1982, ANN ALLERGY, V49, P49
[8]  
HAMBURGER RN, 1991, ANN ALLERGY, V67, P133
[9]  
LIN RY, 1990, ANN ALLERGY, V65, P222
[10]  
MAHAN A, 1990, 47TH ANN M AM COLL A