MYOCARDIAL WASHOUT OF SONICATED IOPAMIDOL DOES NOT REFLECT THE TRANSMURAL DISTRIBUTION OF CORONARY BLOOD-FLOW

被引:8
作者
ROVAI, D [1 ]
GHELARDINI, G [1 ]
LOMBARDI, M [1 ]
TRIVELLA, MG [1 ]
NEVOLA, E [1 ]
TADDEI, L [1 ]
FERDEGHINI, EM [1 ]
DISTANTE, A [1 ]
LABBATE, A [1 ]
机构
[1] UNIV PISA,I-56100 PISA,ITALY
关键词
ECHOCARDIOGRAPHY; CORONARY CIRCULATION; MYOCARDIAL PERFUSION; CONTRAST AGENTS;
D O I
10.1093/eurheartj/14.8.1072
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
It has been shown in previous studies that myocardial contrast echocardiography provides quantitative information on coronary blood flow. However, the ability of contrast echo to assess the transmural (endo/epicardial) distribution of blood flow is still debated. To test this hypothesis, the left circumflex coronary arteries of six anaesthetized open-chested dogs were cannulated and perfused with blood from the femoral artery. At different rates of coronary blood flow, during adenosine-induced coronary vasodilation, sonicated iopamidol and radionuclide labelled microspheres were injected into the coronary cannula, immediately proximal to a mixing chamber. Two-D echo images were digitized and myocardial time-intensity curves were obtained for the endocardial, mid- and epicardial layers. A good correlation existed between contrast washout of the entire ventricular wall and coronary flow (r = 0.85). However, the washout rate from the endo-, mid- and epicardial layers showed weak correlations with corresponding regional blood flows measured by microspheres (r = 0.56, 0.71 and 0.58, respectively). No significant relationship was found between the endo/epicardial washout ratio and the corresponding flow ratio by microspheres. Thus, measurement of the transmural distribution of coronary blood flow by myocardial contrast echocardiography remains an elusive goal. © 1993 The European Society of Cardiology.
引用
收藏
页码:1072 / 1078
页数:7
相关论文
共 50 条
  • [41] MYOCARDIAL ACCUMULATION AND CLEARANCE OF TC-99M TEBOROXIME AT 100-PERCENT, 75-PERCENT, 50-PERCENT AND ZERO CORONARY BLOOD-FLOW IN DOGS
    PIERI, P
    YASUDA, T
    FISCHMAN, AJ
    AHMAD, M
    MOORE, R
    YAOITA, H
    STRAUSS, HW
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1991, 18 (09): : 725 - 731
  • [42] TRANSESOPHAGEAL DOPPLER ECHOCARDIOGRAPHY EVALUATION OF CORONARY BLOOD-FLOW VELOCITY IN BASE-LINE CONDITIONS AND DURING DIPYRIDAMOLE-INDUCED CORONARY VASODILATION
    ILICETO, S
    MARANGELLI, V
    MEMMOLA, C
    RIZZON, P
    CIRCULATION, 1991, 83 (01) : 61 - 69
  • [43] INTEROBSERVER AND INTERSTUDY VARIABILITY OF MYOCARDIAL BLOOD-FLOW AND FLOW-RESERVE MEASUREMENTS WITH NITROGEN 13 AMMONIA-LABELED POSITRON EMISSION TOMOGRAPHY
    SAWADA, S
    MUZIK, O
    BEANLANDS, RSB
    WOLFE, E
    HUTCHINS, GD
    SCHWAIGER, M
    JOURNAL OF NUCLEAR CARDIOLOGY, 1995, 2 (05) : 413 - 422
  • [44] Relative Myocardial Blood Flow by Dynamic Computed Tomographic Perfusion Imaging Predicts Hemodynamic Significance of Coronary Stenosis Better Than Absolute Blood Flow
    Kono, Atsushi K.
    Coenen, Adriaan
    Lubbers, Marisa
    Kurata, Akira
    Rossi, Alexia
    Dharampal, Anoeshka
    Dijkshoorn, Marcel
    van Geuns, Robert-Jan
    Krestin, Gabriel P.
    Nieman, Koen
    INVESTIGATIVE RADIOLOGY, 2014, 49 (12) : 801 - 807
  • [45] Reliability and Reproducibility of Absolute Myocardial Blood Flow: Does It Depend on the PET/CT Technology, the Vasodilator, and/or the Software?
    Gould, K. Lance
    Bui, Linh
    Kitkungvan, Danai
    Patel, Monica B.
    CURRENT CARDIOLOGY REPORTS, 2021, 23 (03)
  • [46] Reliability and Reproducibility of Absolute Myocardial Blood Flow: Does It Depend on the PET/CT Technology, the Vasodilator, and/or the Software?
    K. Lance Gould
    Linh Bui
    Danai Kitkungvan
    Monica B. Patel
    Current Cardiology Reports, 2021, 23
  • [47] A MODEL TO ASSESS INTERVENTIONS TO IMPROVE COLLATERAL BLOOD-FLOW - CONTINUOUS ADMINISTRATION OF AGENTS INTO THE LEFT CORONARY-ARTERY IN DOGS
    UNGER, EF
    BANAI, S
    SHOU, M
    JAKLITSCH, M
    HODGE, E
    CORREA, R
    JAYE, M
    EPSTEIN, SE
    CARDIOVASCULAR RESEARCH, 1993, 27 (05) : 785 - 791
  • [48] LOW POSITIVE END EXPIRATORY PRESSURES IMPROVE THE LEFT-VENTRICULAR WORKLOAD VERSUS CORONARY BLOOD-FLOW RELATIONSHIP
    BENHAIM, SA
    AMAR, R
    SHOFTY, R
    DINNAR, U
    JOURNAL OF CARDIOVASCULAR SURGERY, 1991, 32 (02) : 239 - 245
  • [49] Patients with coronary slow flow phenomenon demonstrate normal myocardial blood flow and arterial wave reflection between acute episodes
    Sharman, James E.
    Moir, Stuart
    Kostner, Karam M.
    Haluska, Brian
    Marwick, Thomas H.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 131 (03) : 321 - 325
  • [50] Diagnosing myocardial ischemia of obstructive coronary artery disease using dynamic computed tomography myocardial perfusion imaging: optimization of relative myocardial blood flow ratio
    Kong, Weifang
    Long, Bingzhu
    Li, Fang
    Shang, Lan
    Chen, Xinyue
    Chughtai, Aamer