A Comparative Study of Treatment of Humeral Shaft Fractures using Interlocking Nail vs. AO Dynamic Compression Plate Fixation

被引:0
|
作者
Iqbal, Mohammad [1 ]
Nawaz, Ayub [2 ]
Mehmood, Tahir [3 ]
Manzoor, Sajid [4 ]
Siddiq, Abu Bakar [1 ]
机构
[1] PGMI, Orthoped, Lahore, Pakistan
[2] Lahore Gen Hosp, PGMI, Orthoped, Lahore, Pakistan
[3] Lahore Jinnah Hosp, Orthopaed, Lahore, Pakistan
[4] Lahore Gen Hosp, Lahore, Pakistan
来源
ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN | 2011年 / 17卷 / 02期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The treatment methods of the fractures of humerus are treated in many ways. Interlocking nails and plates have both stood the test of time but the present study looks at both methods scientifically. Material and Methods: It was a prospective, comparative, study of two groups of patients of fractures of humerus treated with dynamic compression plate versus with interlocking nails. Results: Fractures in both groups healed uneventfully without significant complications. Conclusion: Both modes of treatment can be recommended for the treatment of fractures of the shaft of Humerus with minimal chances of complications.
引用
收藏
页码:162 / 165
页数:4
相关论文
共 50 条
  • [11] Intramedullary fixation of humeral shaft fractures using an inflatable nail
    Lorich, DG
    Geller, DS
    Yacoubian, SV
    Leo, AJ
    Helfet, DL
    ORTHOPEDICS, 2003, 26 (10) : 1011 - 1014
  • [12] Prospective comparative study between antegrade interlocking undreamed nail versus compression plate fixation of acute closed humeral mid third shaft humerus in adults
    Shukur, Ahmad Yaseen
    Majeed, Ghadeer H.
    Al-Edanni, Mohammed Sh.
    Al-Muktar, Sadiq A.
    Alany, Abdulkadr Muhammed Sleman
    Dawood, Muthanna H.
    RAWAL MEDICAL JOURNAL, 2022, 47 (04): : 911 - 916
  • [13] Intramedullary Nail versus Dynamic Compression Plate Fixation in Treating Humeral Shaft Fractures: Grading the Evidence through a Meta-Analysis
    Ma, JianXiong
    Xing, Dan
    Ma, XinLong
    Gao, Feng
    Wei, Qiang
    Jia, HaoBo
    Feng, Rui
    Yu, JingTao
    Wang, Jie
    PLOS ONE, 2013, 8 (12):
  • [14] Antegrade interlocking nailing versus dynamic compression plating for humeral shaft fractures
    Kulkarni, Sunil G.
    Varshneya, Ankit
    Jain, Mohit
    Kulkarni, Vidhisha S.
    Kulkarni, Govind S.
    Kulkarni, Milind G.
    Kulkarni, Ruta M.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (03) : 288 - 291
  • [15] Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail - A prospective, randomised trial
    McCormack, RG
    Brien, D
    Buckley, RE
    McKee, MD
    Powell, J
    Schemitsch, EH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (03): : 336 - 339
  • [16] Comparative results of bracing and interlocking nailing in the treatment of humeral shaft fractures
    Wallny T.
    Sagebiel C.
    Westerman K.
    Wagner U.A.
    Reimer M.
    International Orthopaedics, 1998, 21 (6) : 374 - 379
  • [17] Comparative results of bracing and interlocking nailing in the treatment of humeral shaft fractures
    Wallny, T
    Sagebiel, C
    Westerman, K
    Wagner, UA
    Reimer, M
    INTERNATIONAL ORTHOPAEDICS, 1997, 21 (06) : 374 - 379
  • [18] Plate versus intramedullary nail fixation in the treatment of humeral shaft fractures: an updated meta-analysis
    Ouyang, Hanbin
    Xiong, Jun
    Xiang, Peng
    Cui, Zhuang
    Chen, Liguang
    Yu, Bin
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (03) : 387 - 395
  • [19] The AO/ASIF flexnail.: A flexible intramedullary nail for the treatment of humeral shaft fractures
    Mueller, C. A.
    Henle, P.
    Konrad, G.
    Szarzynski, M.
    Strohm, P. C.
    Suedkamp, N. P.
    UNFALLCHIRURG, 2007, 110 (03): : 219 - 225
  • [20] Humeral shaft fractures treated by dynamic compression plates, Ender nails and interlocking nails
    Ting-Cheng Chao
    Wen-Ying Chou
    Jui-Chang Chung
    Chien-Jen Hsu
    International Orthopaedics, 2005, 29 : 88 - 91