MEASUREMENTS OF FUSION-PRODUCED PROTONS WITH MODERN NUCLEAR TRACK DETECTORS

被引:0
|
作者
ALMASHHADANI, EM
SADOWSKI, M
SZYDLOWSKI, A
机构
关键词
D O I
暂无
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The paper presents results of recent studies on the fusion proton emission from high-current discharges of the PF-type. The protons are registered with modem nuclear track detectors (NTDs) made of CR-39 and PM-355 plastics. The calibration of those detectors is performed with monoenergetic protons of energy ranging from 0.2 up to 4.5 MeV. The measurements of fusion protons are carried out at the PF-360 facility in Swierk.
引用
收藏
页码:180 / 182
页数:3
相关论文
共 50 条
  • [21] CURRENT PHYSICS ISSUES OF FUSION-PRODUCED ALPHA-PARTICLES
    KOLESNICHENKO, YI
    FUSION TECHNOLOGY, 1990, 18 (03): : 371 - 372
  • [22] Bulk etch rate measurements and calibrations of plastic nuclear track detectors
    Balestra, S.
    Cozzi, M.
    Giacomelli, G.
    Giacomelli, R.
    Giorgini, M.
    Kumar, A.
    Mandrioli, G.
    Manzoor, S.
    Margiotta, A. R.
    Medinaceli, E.
    Patrizii, L.
    Popa, V.
    Qureshi, I. E.
    Rana, M. A.
    Sirri, G.
    Spurio, M.
    Togo, V.
    Valieri, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 254 (02): : 254 - 258
  • [23] Gamma and neutron dose measurements with solid state nuclear track detectors
    Kalsi, P. C.
    INDIAN JOURNAL OF PHYSICS AND PROCEEDINGS OF THE INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE, 2009, 83 (06): : 799 - 804
  • [24] Gamma and neutron dose measurements with solid state nuclear track detectors
    P. C. Kalsi
    Indian Journal of Physics, 2009, 83 : 799 - 804
  • [25] Nanoscale measurements of proton tracks using fluorescent nuclear track detectors
    Sawakuchi, Gabriel O.
    Ferreira, Felisberto A.
    McFadden, Conor H.
    Hallacy, Timothy M.
    Granville, Dal A.
    Sahoo, Narayan
    Akselrod, Mark S.
    MEDICAL PHYSICS, 2016, 43 (05) : 2485 - 2490
  • [26] Investigation of x-ray-energy responses of semiconductor detectors under deuterium-tritium fusion-produced neutron irradiation
    Kohagura, J
    Cho, T
    Hirata, M
    Numakura, T
    Minami, R
    Yoshida, M
    Nagashima, S
    Watanabe, H
    Yatsu, K
    Miyoshi, S
    Kondoh, T
    Nishitani, T
    Takeuchi, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 805 - 808
  • [27] Single track coincidence measurements of fluorescent and plastic nuclear track detectors in therapeutic carbon beams
    Osinga, J. -M.
    Ambrozova, I.
    Brabcova, K. Pachnerova
    Akselrod, M. S.
    Jaekel, O.
    Davidkova, M.
    Greilich, S.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [28] Stochastic simulation of track density in nuclear track detectors for 10B measurements in autoradiography
    Saint Martin, G.
    Portu, A.
    Santa Cruz, G. A.
    Bernaola, O. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (23): : 2781 - 2785
  • [29] 3D track reconstruction of neutron-induced recoil protons in fluorescent nuclear track detectors (FNTDs)
    Stabilini, A.
    Akselrod, M. S.
    Fomenko, V
    Greilich, S.
    Harrison, J.
    Yukihara, E. G.
    RADIATION MEASUREMENTS, 2020, 137 (137)
  • [30] Response of CR-39 nuclear track detectors to protons with non-normal incidence
    Przybocki, R.
    Johnson, M. Gatu
    Sutcliffe, G.
    Lahmann, B.
    Seguin, F. H.
    Frenje, J.
    Adrian, P.
    Johnson, T. M.
    Pearcy, J.
    Kabadi, N. V.
    Birkel, A.
    Petrasso, R. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (01):