MEASUREMENT OF VOLATILE ORGANICS AT PART PER BILLION CONCENTRATIONS USING A COLD TRAP INLET AND HIGH-SPEED GAS-CHROMATOGRAPHY

被引:9
作者
MOURADIAN, RF [1 ]
LEVINE, SP [1 ]
KE, HQ [1 ]
ALVORD, HH [1 ]
机构
[1] UNIV MICHIGAN,SCH PUBL HLTH,DEPT ENVIRONM & IND HLTH,ANN ARBOR,MI 48109
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 1991年 / 41卷 / 08期
关键词
D O I
10.1080/10473289.1991.10466901
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Direct inlet gas chromatography (GC) is becoming one of the most frequently used techniques for measurement of volatile organics in air. Although GC is an effective tool, its usefulness as a field method can be limited by retention times of several minutes or more, and by the limits of detection. In order to address these issues, a high speed GC system featuring a capillary cold trap inlet and variable speed electrometer-amplifier was developed and tested. The gas cooled inlet was used to collect and focus organic vapors from injection volumes of up to 1 ml. Resistance heating of the metal cold trap produced a narrow injection band that allowed simple separations to be completed in 5 to 20 seconds. Use of a variable speed electrometer-amplifier allowed the response time and noise suppression characteristics to be adjusted to the needs of the specific analysis. Simple mixtures of organics including aromatics, alkanes and chlorinated hydrocarbons were separated in 20 seconds or less. The limits of detection for 13 test compounds ranged from less than 1 part per billion by volume (ppbv) to about 50 ppbv. Data presented here indicate that high speed GC using a cold trap inlet may be a feasible approach for near real-time measurement of volatile organics in ambient air.
引用
收藏
页码:1067 / 1072
页数:6
相关论文
共 30 条
[11]   LIMIT OF DETECTION [J].
LONG, GL ;
WINEFORDNER, JD .
ANALYTICAL CHEMISTRY, 1983, 55 (07) :A712-+
[12]   A HIGH-RESOLUTION GC-ANALYSIS METHOD FOR DETERMINATION OF C2-C10 HYDROCARBONS IN AIR SAMPLES [J].
MATUSKA, P ;
KOVAL, M ;
SEILER, W .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (10) :577-583
[13]  
MCCLENNY WA, 1987, APR EPA APCA S MEAS
[14]  
MILLER JC, 1987, STATISTICS ANAL CHEM
[15]   MEASUREMENT OF ORGANIC VAPORS AT SUB-TLV CONCENTRATIONS USING FAST GAS-CHROMATOGRAPHY [J].
MOURADIAN, RF ;
LEVINE, SP ;
SACKS, RD ;
SPENCE, MW .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1990, 51 (02) :90-95
[16]   EVALUATION OF A NITROGEN-COOLED, ELECTRICALLY HEATED COLD TRAP INLET FOR HIGH-SPEED GAS-CHROMATOGRAPHY [J].
MOURADIAN, RF ;
LEVINE, SP ;
SACKS, RD .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (12) :643-648
[17]   DETERMINATION OF AIRBORNE ORGANIC VAPOR MIXTURES USING CHARCOAL TUBES [J].
MUELLER, FX ;
MILLER, JA .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1979, 40 (05) :380-386
[18]   SAMPLE INTEGRITY OF TRACE LEVEL VOLATILE ORGANIC-COMPOUNDS IN AMBIENT AIR STORED IN SUMMA POLISHED CANISTERS [J].
OLIVER, KD ;
PLEIL, JD ;
MCCLENNY, WA .
ATMOSPHERIC ENVIRONMENT, 1986, 20 (07) :1403-1411
[19]  
PARKES DG, 1976, AIHAJ, V15, P165
[20]   AMBIENT AIR ANALYSES USING NONSPECIFIC FLAME IONIZATION AND ELECTRON-CAPTURE DETECTION COMPARED TO SPECIFIC DETECTION BY MASS-SPECTROSCOPY [J].
PLEIL, JD ;
OLIVER, KD ;
MCCLENNY, WA .
JAPCA-THE INTERNATIONAL JOURNAL OF AIR POLLUTION CONTROL AND HAZARDOUS WASTE MANAGEMENT, 1988, 38 (08) :1006-1010