STUDIES ON THE DETERMINATION OF INORGANIC ANIONS BY CAPILLARY ELECTROPHORESIS

被引:54
作者
BENZ, NJ
FRITZ, JS
机构
[1] IOWA STATE UNIV SCI & TECHNOL,DEPT CHEM,AMES,IA 50011
[2] IOWA STATE UNIV SCI & TECHNOL,AMES LAB,AMES,IA 50011
关键词
D O I
10.1016/0021-9673(94)80271-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In order to separate anions effectively it is usually necessary to eliminate or reverse the direction of electroosmotic flow (EOF) resulting from attraction of cations to the negatively charged surface of a silica capillary. Previous workers have accomplished this by adding a quaternary ammonium salt (Q(+)) as an EOF ''modifier''. Under typical experimental conditions, a concentration of Q(+) > 0.25 mM is required to reverse the EOF direction. Addition of a low percentage of 1-butanol to the aqueous electrolyte was found to reduce the EOF. A combination of butanol and a very low concentration of Q(+) (typically 0.03 mM) was found to be particularly effective in controlling EOF and in giving effective separations of complex mixtures of anions. The probable mechanism of the butanol-Q(+) effect is discussed.
引用
收藏
页码:437 / 443
页数:7
相关论文
共 28 条
[1]   DETERMINATION OF CATIONS AND ANIONS BY CAPILLARY ELECTROPHORESIS COMBINED WITH SUPPRESSED CONDUCTIVITY DETECTION [J].
AVDALOVIC, N ;
POHL, CA ;
ROCKLIN, RD ;
STILLIAN, JR .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :1470-1475
[2]   NEW APPROACH TO THE ANALYSIS OF LOW-LEVELS OF ANIONS IN WATER [J].
BONDOUX, G ;
JANDIK, P ;
JONES, WR .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :79-88
[3]   CAPILLARY ZONE ELECTROPHORETIC SEPARATIONS OF PROTEINS IN POLYETHYLENE GLYCOL-MODIFIED CAPILLARIES [J].
BRUIN, GJM ;
CHANG, JP ;
KUHLMAN, RH ;
ZEGERS, K ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1989, 471 :429-436
[4]   EFFECTS OF CARRIER ELECTROLYTE-COMPOSITION ON SEPARATION SELECTIVITY IN CAPILLARY ZONE ELECTROPHORESIS OF LOW-MOLECULAR-MASS ANIONS [J].
BUCHBERGER, W ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :59-64
[5]   EFFECT OF ADDITION OF ORGANIC-SOLVENT ON THE SEPARATION OF POSITIONAL ISOMERS IN HIGH-VOLTAGE CAPILLARY ZONE ELECTROPHORESIS [J].
FUJIWARA, S ;
HONDA, S .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :487-490
[6]   PARAMETERS INFLUENCING SEPARATION AND DETECTION OF ANIONS BY CAPILLARY ELECTROPHORESIS [J].
HARROLD, MP ;
WOJTUSIK, MJ ;
RIVIELLO, J ;
HENSON, P .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :463-471
[7]   EFFECTS OF BUFFER PH ON ELECTROOSMOTIC FLOW-CONTROL BY AN APPLIED RADIAL VOLTAGE FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HAYES, MA ;
KHETERPAL, I ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1993, 65 (01) :27-31
[8]   ELECTROOSMOTIC FLOW-CONTROL AND MONITORING WITH AN APPLIED RADIAL VOLTAGE FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HAYES, MA ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1992, 64 (05) :512-516
[9]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[10]   QUANTITATIVE-ANALYSIS OF LOW-MOLECULAR WEIGHT CARBOXYLIC-ACIDS BY CAPILLARY ZONE ELECTROPHORESIS CONDUCTIVITY DETECTION [J].
HUANG, XH ;
LUCKEY, JA ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1989, 61 (07) :766-770