Imaging of the Thoracic Aorta with Time-Resolved Three-Dimensional Phase-Contrast MRI: A Review

被引:26
作者
Hope, Thomas A. [1 ]
Herfkens, Robert J. [2 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
4D flow; phase contrast; thoracic aorta;
D O I
10.1053/j.semtcvs.2008.11.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Time-resolved three-dimensional (3D) phase-contrast (PC) magnetic resonance imaging (MRI), or four-dimensional (4D) flow, is able to provide robust 3D images with three-directional velocities. This review discusses the technique and application of 4D flow in the imaging of thoracic aortic pathologies. It has been instrumental in describing normal flow patterns throughout the cardiac cycle in the ascending and descending aorta and has shown the variety of flow patterns that exist in ascending aortic aneurysms. © 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:358 / 364
页数:7
相关论文
共 31 条
  • [1] RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING
    BAILES, DR
    GILDERDALE, DJ
    BYDDER, GM
    COLLINS, AG
    FIRMIN, DN
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) : 835 - 838
  • [2] Time-resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging
    Bammer, Roland
    Hope, Thomas A.
    Aksoy, Murat
    Alley, Marcus T.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) : 127 - 140
  • [3] Concomitant gradient terms in phase contrast MR: Analysis and correction
    Bernstein, MA
    Zhou, XHJ
    Polzin, JA
    King, KF
    Ganin, A
    Pelc, NJ
    Glover, GH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) : 300 - 308
  • [4] Four-dimensional magnetic resonance velocity mapping of blood flow patterns in the aorta in patients with atherosclerotic coronary artery disease compared to age-matched normal subjects
    Bogren, HG
    Buonocore, MH
    Valente, RJ
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (04) : 417 - 427
  • [5] Bogren HG, 1999, J MAGN RESON IMAGING, V10, P861, DOI 10.1002/(SICI)1522-2586(199911)10:5<861::AID-JMRI35>3.0.CO
  • [6] 2-E
  • [7] MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE
    BRYANT, DJ
    PAYNE, JA
    FIRMIN, DN
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) : 588 - 593
  • [8] Multidirectional flow analysis by cardiovascular magnetic resonance in aneurysm development following repair of aortic coarctation
    Frydrychowicz, Alex
    Arnold, Raoul
    Hirtler, Daniel
    Schlensak, Christian
    Stalder, Aurelien F.
    Hennig, Juergen
    Langer, Mathias
    Markl, Michael
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
  • [9] GLOVER GH, 1988, Patent No. 4663691
  • [10] Three-dimensional flow characterization using vector pattern matching
    Heiberg, E
    Ebbers, T
    Wigström, L
    Karlsson, M
    [J]. IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2003, 9 (03) : 313 - 319