Addressing spatiotemporal distortion of high-speed tissue motion in B-mode ultrasound

被引:0
作者
Mallory, Ann [1 ,2 ]
Donnelly, Bruce [3 ,6 ]
Liu, Jun [4 ]
Bahner, David [5 ]
Moorhouse, Kevin [6 ]
Dupaix, Rebecca [2 ]
机构
[1] Transportat Res Ctr Inc, POB B-37,10820 State Route 347, East Liberty, OH 43319 USA
[2] Ohio State Univ, Dept Mech & Aerosp Engn, E310 Scott Lab, Columbus, OH 43210 USA
[3] Biomech Res Associates, 22 West Lincoln Ave, Delaware, OH 43015 USA
[4] Ohio State Univ, Dept Biomed Engn, 1080 Carmack Rd, Columbus, OH 43210 USA
[5] Ohio State Univ, Med Ctr, 460 West 10th Ave, Columbus, OH 43210 USA
[6] Natl Highway Traff Safety Adm, POB B-37,10820 State Route 347, East Liberty, OH 43319 USA
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2018年 / 4卷 / 05期
关键词
ultrasound; high-frequency; B-mode; spatiotemporal distortion; correction; rolling shutter; injury biomechanics;
D O I
10.1088/2057-1976/aad925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The sequential excitation of transducer elements in linear ultrasound arrays can produce distorted images in B-mode since the A-lines in an image frame are not captured at the same time. If the imaged tissue is moving laterally during image acquisition, substantial distortion can occur and lead to errors in tissue displacement and velocity measurements, particularly for high-speed tissue motion such as in injury biomechanics tests. A method for correcting for this distortion in tracked time-series displacement data was developed for systems in which each A-line of the image is completed at a time proportional to its lateral position across the transducer linear array. The proposed method involves estimating more precisely the time at which each point in the image was captured, rather than relying on the time elapsed between image frames to estimate timing. The developed method was evaluated using results from motion tests of human dura imaged using a Vevo 2100 Imaging System at a frame rate of 865 frames per second. At tissue speeds ranging from 0.2 m s(-)1 to 2.3 m s(-1), tracking of tissue displacement without correction resulted in mean displacement measurement error of 17%. Correction using proposed methods reduced error to a mean of 2%. This correction concept has the potential to improve the accuracy of velocity or displacement measurements in any B-mode imaging application where tissue velocity is high relative to ultrasound sweep velocity including in injury biomechanics and cardiac biomechanics research.
引用
收藏
页数:9
相关论文
共 13 条
[1]   A new method to assess the deformations of internal organs of the abdomen during impact [J].
Beillas, P. ;
Helfenstein, C. ;
Rongieras, F. ;
Gennisson, J. -L. ;
Tanter, M. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 :202-203
[2]   Ultrahigh frame rate retrospective ultrasound microimaging and blood flow visualization in mice in vivo [J].
Cherin, Emmanuel ;
Williams, Ross ;
Needles, Andrew ;
Liu, Godwin ;
White, Christopher ;
Brown, Allison S. ;
Zhou, Yu-Qing ;
Foster, F. Stuart .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (05) :683-691
[3]   Suppressing Rolling-Shutter Distortion of CMOS Image Sensors by Motion Vector Detection [J].
Chun, Jung-Bum ;
Jung, Hunjoon ;
Kyung, Chong-Min .
IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 2008, 54 (04) :1479-1487
[4]   A novel interpolation strategy for estimating subsample speckle motion [J].
Geiman, BJ ;
Bohs, LN ;
Anderson, ME ;
Breit, SM ;
Trahey, GE .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) :1541-1552
[5]  
Hardy W, 2007, THESIS
[6]   The effect of object speed and direction on the performance of 3D speckle tracking using a 3D swept-volume ultrasound probe [J].
Harris, Emma J. ;
Miller, Naomi R. ;
Bamber, Jeffrey C. ;
Symonds-Tayler, J. Richard N. ;
Evans, Philip M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22) :7127-7143
[7]   Observation of the internal response of the kidney during compressive loading using ultrafast ultrasonography [J].
Helfenstein-Didier, C. ;
Tanter, M. ;
Gennisson, J-L ;
Beillas, P. .
JOURNAL OF BIOMECHANICS, 2015, 48 (10) :1852-1859
[8]  
Kennedy Eric A, 2006, Stapp Car Crash J, V50, P651
[9]   Estimation of 2D strain in abdominal organs during an impact based on ultrafast ultrasound images: a physical landmark-based approach [J].
Le Ruyet, A. ;
Beillas, P. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 :2048-2049
[10]   Analysis and compensation of rolling shutter effect [J].
Liang, Chia-Kai ;
Chang, Li-Wen ;
Chen, Homer H. .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2008, 17 (08) :1323-1330