VERTICAL HYDRAULIC GENERATORS EXPERIENCE WITH DYNAMIC AIR GAP MONITORING

被引:30
作者
POLLOCK, GB
LYLES, JF
机构
[1] Ontario Hydro, Toronto
关键词
AIR GAP; MONITORING; DYNAMIC; HYDRAULIC; GENERATOR; ROTOR; STATOR;
D O I
10.1109/60.182648
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Until recently, dynamic monitoring of the rotor to stator air gap of hydraulic generators was not practical. Cost effective and reliable dynamic air gap monitoring equipment has been developed in recent years. Dynamic air gap monitoring was originally justified because of the desire of the owner to minimize the effects of catastrophic air gap failure. However, monitoring air gaps on a time basis has been shown to be beneficial by assisting in the assessment of hydraulic generator condition. The air gap monitor provides useful information on rotor and stator condition and generator vibration. The data generated by air gap monitors will assist managers in the decision process with respect to the timing and extent of required maintenance for a particular generating unit.
引用
收藏
页码:660 / 668
页数:9
相关论文
共 6 条
[1]  
BISSONNETTE M, 1989, 1ST P INT MACH MON D, P261
[2]  
BOYD JM, 1987, 1987 EPRI HYDR O M W
[3]   APPLICATION OF PARTIAL DISCHARGE TESTING TO HYDRO GENERATOR MAINTENANCE [J].
KURTZ, M ;
LYLES, JF ;
STONE, GC .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (08) :2148-2157
[4]  
MENARD P, 1989, SEP INT C LARG HIGH
[5]   EXCESSIVE SHAFT THROW PROBLEM OF GENERATORS FOR KPONG GENERATING-STATION, VRA, GHANA [J].
OKAZAKI, S ;
NAKANO, F .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (09) :3226-3231
[6]  
TALAS P, 1986 IEEE PES JOINT