RADIATION FLUENCE ANISOTROPY OF IR-192 AND AU-198 SEEDS

被引:0
|
作者
GROMADZKI, Z
LING, C
RUSTGI, S
机构
[1] GEORGETOWN UNIV HOSP,DEPT RADIAT MED,WASHINGTON,DC 20007
[2] GEORGE WASHINGTON UNIV HOSP,DEPT RADIOL,WASHINGTON,DC 20037
[3] UNIV TEXAS,MD ANDERSON HOSP & TUMOR INST,HOUSTON,TX 77030
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:570 / 570
页数:1
相关论文
共 50 条
  • [41] DOSE AND DOSE DISTRIBUTION IN THE RADIATION-FIELD CLOSE TO IR-192 SOURCES
    KNESCHAUREK, P
    LINDNER, H
    STRAHLENTHERAPIE, 1985, 161 (11) : 706 - 710
  • [42] Endocavitary Ir-192 radiation and laser treatment for palliation of obstructive rectal cancer
    Mischinger, HJ
    Hauser, H
    Cerwenka, H
    Stucklschweiger, G
    Geyer, E
    Schweiger, W
    Rosanelli, G
    Kohek, PH
    Werkgartner, H
    Hackl, A
    EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 1997, 23 (05): : 428 - 431
  • [43] Monte Carlo dosimetric study of best industries and alpha omega Ir-192 brachytherapy seeds
    Ballester, F
    Granero, D
    Pérez-Calatayud, J
    Casal, E
    Puchades, V
    MEDICAL PHYSICS, 2004, 31 (12) : 3298 - 3305
  • [44] Radiation safety of personnel during catheter-based Ir-192 coronary brachytherapy
    Jani, SK
    Steuterman, S
    Huppe, GB
    Chu, GL
    JOURNAL OF INVASIVE CARDIOLOGY, 2000, 12 (05) : 286 - 290
  • [45] RADIATION-INJURY FROM ACUTE EXPOSURE TO AN IR-192 SOURCE - CASE HISTORY
    ANNAMALAI, M
    IYER, PS
    PANICKER, TMR
    HEALTH PHYSICS, 1978, 35 (02): : 387 - 389
  • [46] Response of the alanine/ESR dosimeter to radiation from an Ir-192 HDR brachytherapy source
    Anton, M.
    Hackel, T.
    Zink, K.
    von Voigts-Rhetz, P.
    Selbach, H-J
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (01) : 175 - 193
  • [47] 5-YEARS EXPERIENCE WITH GOLD BUTTON TECHNIQUE FOR INTRAORAL INTERSTITIAL IMPLANTS WITH IR-192 SEEDS
    KUMAR, PP
    HENSCHKE, UK
    RADIOLOGY, 1977, 124 (01) : 227 - 229
  • [48] ANISOTROPY FUNCTIONS FOR PD-103, I-125, AND IR-192 INTERSTITIAL BRACHYTHERAPY SOURCES
    NATH, R
    MEIGOONI, AS
    MUENCH, P
    MELILLO, A
    MEDICAL PHYSICS, 1993, 20 (05) : 1465 - 1473
  • [49] Radiochromic film measurement of anisotropy function for high-dose-rate Ir-192 brachytherapy source
    Sharma, SD
    Bianchi, C
    Conte, L
    Novario, R
    Bhatt, BC
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17) : 4065 - 4072
  • [50] USE OF PERCUTANEOUS TRANSPERINEAL AU-198 SEEDS TO TREAT RECURRENT PROSTATE ADENOCARCINOMA AFTER FAILURE OF DEFINITIVE RADIOTHERAPY
    LOENING, SA
    TURNER, JW
    PROSTATE, 1993, 23 (04) : 283 - 290