EXTERNAL POWER FREQUENCY MAGNETIC-FIELD-INDUCED JITTER ON COMPUTER MONITORS

被引:10
作者
SANDSTROM, M
MILD, KH
SANDSTROM, M
BERGLUND, A
机构
[1] National Institute of Occupational Health, Umeå, S-907 13
关键词
JITTER; MAGNETIC FIELD; VDT;
D O I
10.1080/01449299308924400
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Power frequency magnetic fields with flux densities greater than 0.5 mut are not uncommon in offices. This level has been shown to induce jitter on VDT monitors. In the present project, these magnetic field-induced disturbances have been studied in the laboratory in order to establish a firm technical basis for future studies of the disturbance's influence on eye strain in VDT workers. Eight volunteers judged the occurrence of distortion when an applied external magnetic field was varied both in amplitude and frequency for 8 investigated VDT screens. The level of the external 50 Hz magnetic field when the distortion was detectable ranged from 0.6 to 1.1 muT. If the screen was viewed through a stereomicroscope (25 x magnification), the corresponding level was in the order of 0.2 muT. If the frequency difference between the external magnetic field and the refresh rate of the screen is only +/- 1-2 Hz, the disturbance is noticeable at even lower flux densities.
引用
收藏
页码:359 / 363
页数:5
相关论文
共 10 条
[1]  
BAISHIKI RS, 1987, IEEE T POW DELIV, P558
[2]   HUMAN ELECTRORETINOGRAM RESPONSES TO VIDEO DISPLAYS, FLUORESCENT LIGHTING, AND OTHER HIGH-FREQUENCY SOURCES [J].
BERMAN, SM ;
GREENHOUSE, DS ;
BAILEY, IL ;
CLEAR, RD ;
RAASCH, TW .
OPTOMETRY AND VISION SCIENCE, 1991, 68 (08) :645-662
[3]   WORKSTATION VARIABLES AND VISUAL DISCOMFORT ASSOCIATED WITH VDTS [J].
COLLINS, M ;
BROWN, B ;
BOWMAN, K ;
CARKEET, A .
APPLIED ERGONOMICS, 1990, 21 (02) :157-161
[4]  
*EL POW RES I, 1991, FIELD EH RES HIGH U
[5]  
ERIKSSON S, 1987, WORK DISPLAY UNITS 8
[6]   WORK WITH VIDEO DISPLAY TERMINALS AMONG OFFICE EMPLOYEES .1. SUBJECTIVE SYMPTOMS AND DISCOMFORT [J].
KNAVE, BG ;
WIBOM, RI ;
VOSS, M ;
HEDSTROM, LD ;
BERGQVIST, UOV .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1985, 11 (06) :457-466
[7]  
*MPR 2, 1990, TEST METH VIS DISPL, P8
[8]  
Rubino GF, 1989, B OCUL, V68, P113
[9]  
SANDSTROM M, 1993, IN PRESS IEEE T EMC
[10]  
1990, OFFICIAL J EUROPEAN, V1