3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY IN CAROTID-ARTERY SURGERY - A COMPARISON WITH DIGITAL SUBTRACTION ANGIOGRAPHY

被引:29
|
作者
CHIESA, R
MELISSANO, G
CASTELLANO, R
TRIULZI, F
ANZALONE, N
VEGLIA, F
SCOTTI, G
GROSSI, A
机构
[1] Institute for Cardiovascular and Respiratory Disease, University of Milan, Scientific Institute H. San Raffaele, Milan
[2] Department of Neuroradiology, University of Milan, Scientific Institute H. San Raffaele, Milan
[3] Unit of Epidemiology, University of Milan, Scientific Institute H. San Raffaele, Milan
来源
EUROPEAN JOURNAL OF VASCULAR SURGERY | 1993年 / 7卷 / 02期
关键词
MAGNETIC RESONANCE ANGIOGRAPHY; CAROTID ARTERY SURGERY; DIGITAL SUBTRACTION ANGIOGRAPHY;
D O I
10.1016/S0950-821X(05)80758-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Three dimensional time-of-flight magnetic resonance angiography (MRA) and intra-arterial digital subtraction angiography (DSA), considered the gold-standard technique, were compared for pre- and postoperative evaluation of the carotid bifurcation. Images of suitable quality of 194 bifurcations were available with both techniques. Percentage stenosis was graded into 5 groups: A = 0-29%, B = 30-59%, C = 60-89%, D = 90-99%, E = 100% (occlusion). Preoperative MRA (126 bifurcations) overgraded the stenosis in 14 cases and undergraded it in 11. The two techniques agreed in 101 cases and the extent of misgrading was never more than one category. Regression analysis showed a good correlation between the two methods. Severe ulceration was better identified by DSA. As far as the surgical indication was concerned, MRA had a sensitivity of 92.6% and a specificity of 98.3%. In 68 operated cases, postoperative MRA and intraoperative completion angiography showed a satisfactory endarterectomy with no residual stenosis in any of the cases. In conclusion, MRA seems an accurate modality for imaging of carotid bifurcations. Significant limitations still exist for an adequate demonstration of intracranial circulation. © 1993 Grune & Stratton Ltd.
引用
收藏
页码:171 / 176
页数:6
相关论文
共 50 条
  • [1] EVALUATION OF THE CAROTID-ARTERY BIFURCATION - COMPARISON OF MAGNETIC-RESONANCE ANGIOGRAPHY AND DIGITAL SUBTRACTION ARCH AORTOGRAPHY
    KIDO, DK
    BARSOTTI, JB
    RICE, LZ
    ROTHENBERG, BM
    PANZER, RJ
    SOUZA, SP
    DUMOULIN, CL
    NEURORADIOLOGY, 1991, 33 (01) : 48 - 51
  • [2] Comparison of two-dimensional time-of-flight dynamic magnetic resonance angiography with digital subtraction angiography in popliteal artery entrapment syndrome
    Forster, BB
    Houston, JG
    Machan, LS
    Doyle, L
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1997, 48 (01): : 11 - 18
  • [3] CLINICAL UTILITY OF 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY FOR THE EVALUATION OF INTRACRANIAL
    FUTATSUYA, R
    SETO, H
    KAMEI, T
    NAKASHIMA, A
    KAKISHITA, M
    KURIMOTO, M
    ENDOH, S
    CLINICAL IMAGING, 1994, 18 (02) : 101 - 106
  • [4] USEFULNESS OF 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY FOR EVALUATION OF CAROTID-ARTERY BIFURCATION STENOSIS
    UEHARA, T
    TABUCHI, M
    OHSUMI, Y
    YONEDA, Y
    MORI, E
    CEREBROVASCULAR DISEASES, 1995, 5 (03) : 199 - 203
  • [5] Mild carotid artery atherosclerosis -: Assessment by 3-dimensional time-of-flight magnetic resonance angiography, with reference to intravascular ultrasound imaging and contrast angiography
    Räsänen, HT
    Manninen, HI
    Vanninen, RL
    Vainio, P
    Berg, M
    Saari, T
    STROKE, 1999, 30 (04) : 827 - 833
  • [6] MAGNETIC-RESONANCE ANGIOGRAPHY OF EXTRACRANIAL CAROTID AND VERTEBRAL ARTERIES, INCLUDING THEIR ORIGINS - COMPARISON WITH DIGITAL SUBTRACTION ANGIOGRAPHY
    FURUYA, Y
    ISODA, H
    HASEGAWA, S
    TAKAHASHI, M
    KANEKO, M
    UEMURA, K
    NEURORADIOLOGY, 1992, 35 (01) : 42 - 45
  • [7] DETECTION OF OCCLUSIVE LESIONS IN INTRACRANIAL-ARTERIES BY 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY
    UEHARA, T
    MORI, E
    TABUCHI, M
    OHSUMI, Y
    YAMADORI, A
    CEREBROVASCULAR DISEASES, 1994, 4 (05) : 365 - 370
  • [8] MAGNETIC-RESONANCE ANGIOGRAPHY OF INTRACRANIAL ANEURYSMS - COMPARISON WITH INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY
    SCHUIERER, G
    HUK, WJ
    LAUB, G
    NEURORADIOLOGY, 1992, 35 (01) : 50 - 54
  • [9] Follow-up after embolization of ruptured intracranial aneurysms: A prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography
    Zbigniew Serafin
    Piotr Strześniewski
    Władysław Lasek
    Wojciech Beuth
    Neuroradiology, 2012, 54 : 1253 - 1260
  • [10] Follow-up after embolization of ruptured intracranial aneurysms: A prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography
    Serafin, Zbigniew
    Strzesniewski, Piotr
    Lasek, Wadyslaw
    Beuth, Wojciech
    NEURORADIOLOGY, 2012, 54 (11) : 1253 - 1260