摘要
Total hip arthroplasty is an increasingly common procedure used to address degenerative changes in the hip joint due to osteoarthritis. Although generally associated with good results, among the challenges associated with hip arthroplasty are accurate measurement of biomechanical parameters such as leg length, offset, and cup position, discrepancies of which can lead to significant long-term consequences such as pain, instability, neurological deficits, dislocation, and revision surgery, as well as patient dissatisfaction and, increasingly, litigation. Current methods of managing these parameters are limited, with manual methods such as outriggers or calipers being used to monitor leg length; however, these are susceptible to small intraoperative changes in patient position and are therefore inaccurate. Computer-assisted navigation, while offering improved accuracy, is expensive and cumbersome, in addition to adding significantly to procedural time. To address the technological gap in hip arthroplasty, a new intraoperative navigation tool (Intellijoint HIP (R)) has been developed. This innovative, 3D mini-optical navigation tool provides real-time, intraoperative data on leg length, offset, and cup position and allows for improved accuracy and precision in component selection and alignment. Benchtop and simulated clinical use testing have demonstrated excellent accuracy, with the navigation tool able to measure leg length and offset to within <1 mm and cup position to within <1 degrees in both anteversion and inclination. This study describes the indications, procedural technique, and early accuracy results of the Intellijoint HIP surgical tool, which offers an accurate and easy-to-use option for hip surgeons to manage leg length, offset, and cup position intraoperatively.
引用
收藏
页码:401 / 408
页数:8
相关论文
共 44 条
[1]   Interest of an intraoperative limb-length and offset measurement device in total hip arthroplasty [J].
Barbier, O. ;
Ollat, D. ;
Versier, G. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (04) :398-404
[2]   The Epidemiology of Revision Total Hip Arthroplasty in the United States [J].
Bozic, Kevin J. ;
Kurtz, Steven M. ;
Lau, Edmund ;
Ong, Kevin ;
Vail, Thomas P. ;
Berry, Daniel J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) :128-133
[3]   Effect of Femoral Offset on Pain and Function After Total Hip Arthroplasty [J].
Cassidy, Kevin A. ;
Noticewala, Manish S. ;
Macaulay, William ;
Lee, Jonathan H. ;
Geller, Jeffrey A. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (10) :1863-1869
[4]   Revision total hip arthroplasty - Hospital cost and reimbursement analysis [J].
Crowe, JF ;
Sculco, TP ;
Kahn, B .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (413) :175-182
[5]  
Danner D, 1999, REVISION TOTAL HIP A, P583
[6]   Dislocation Following Total Hip Replacement [J].
Dargel, Jens ;
Oppermann, Johannes ;
Brueggemann, Gert-Peter ;
Eysel, Peer .
DEUTSCHES ARZTEBLATT INTERNATIONAL, 2014, 111 (51-52) :884-890
[7]   Critical review of the current practice for computer-assisted navigation in total knee replacement surgery: Cost-effectiveness and clinical outcome [J].
Desai A.S. ;
Dramis A. ;
Kendoff D. ;
Board T.N. .
Current Reviews in Musculoskeletal Medicine, 2011, 4 (1) :11-15
[8]   Early assessment of the likely cost-effectiveness of a new technology: A Markov model with probabilistic sensitivity analysis of computer-assisted total knee replacement [J].
Dong, HJ ;
Buxton, M .
INTERNATIONAL JOURNAL OF TECHNOLOGY ASSESSMENT IN HEALTH CARE, 2006, 22 (02) :191-202
[9]   Health-related quality of life in total hip and total knee arthroplasty - A qualitative and systematic review of the literature [J].
Ethgen, O ;
Bruyere, O ;
Richy, F ;
Dardennes, C ;
Reginster, JY .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05) :963-974
[10]   Relative Importance of Gait vs. Joint Positioning on Hip Contact Forces after Total Hip Replacement [J].
Foucher, Kharma C. ;
Hurwitz, Debra E. ;
Wimmer, Markus A. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (12) :1576-1582