IMPROVEMENT OF ONLINE DETECTION IN HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY - UV ABSORPTIOMETRY AND EVAPORATIVE LIGHT-SCATTERING DETECTION

被引:21
作者
DROGUE, S [1 ]
ROLET, MC [1 ]
THIEBAUT, D [1 ]
ROSSET, R [1 ]
机构
[1] ECOLE SUPER PHYS & CHIM IND,CHIM ANALYT LAB,10 RUE VAUQUELIN,F-75231 PARIS 05,FRANCE
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 538卷 / 01期
关键词
D O I
10.1016/S0021-9673(01)91625-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Improvements in analytical high-speed counter-current chromatography involve reduction of the column volume and a high revolution speed in order to decrease the time of analysis. Continuous detection should be performed instead of laborious fraction collection before reading the UV absorbance of the fractions. In this work on-line UV absorptiometry was performed by adding a "make-up" solvent to the column effluent in order to obtain a homogeneous medium before the detection is carried out. The first attempt to use an evaporative light-scattering detector is discussed.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 27 条
[1]   CENTRIFUGAL PARTITION CHROMATOGRAPHY .1. GENERAL FEATURES [J].
BERTHOD, A ;
ARMSTRONG, DW .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (03) :547-566
[2]   SUPERCRITICAL FLUID CHROMATOGRAPHY LIGHT-SCATTERING DETECTOR - A PROMISING COUPLING FOR POLAR COMPOUNDS ANALYSIS WITH PACKED-COLUMNS [J].
CARRAUD, P ;
THIEBAUT, D ;
CAUDE, M ;
ROSSET, R ;
LAFOSSE, M ;
DREUX, M .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1987, 25 (09) :395-398
[3]   EVAPORATIVE ANALYZER AS A MASS DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
CHARLESWORTH, JM .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1414-1420
[4]   ESTIMATION OF THE BAND BROADENING CONTRIBUTION OF HPLC EQUIPMENT TO COLUMN ELUTION PROFILES [J].
CLAESSENS, HA ;
CRAMERS, CA ;
KUYKEN, MAJ .
CHROMATOGRAPHIA, 1987, 23 (03) :189-194
[5]   PURIFICATION OF NITROPHENYLVALERIC ACID REACTION MIXTURES BY COUNTER-CURRENT CHROMATOGRAPHY [J].
CONWAY, WD ;
KLINGMAN, JD ;
GRECO, D ;
HUH, KS .
JOURNAL OF CHROMATOGRAPHY, 1989, 484 :391-397
[6]  
DREUX M, COMMUNICATION
[7]   INFLUENCE OF VARIOUS PARAMETERS ON THE RESPONSE FACTORS OF THE EVAPORATIVE LIGHT-SCATTERING DETECTOR FOR A NUMBER OF NON-VOLATILE COMPOUNDS [J].
GUIOCHON, G ;
MOYSAN, A ;
HOLLEY, C .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (12) :2547-2570
[8]   IMPROVED HIGH-SPEED COUNTER-CURRENT CHROMATOGRAPH WITH 3 MULTILAYER COILS CONNECTED IN SERIES .2. SEPARATION OF VARIOUS BIOLOGICAL SAMPLES WITH A SEMIPREPARATIVE COLUMN [J].
ITO, Y ;
OKA, H ;
LEE, YW .
JOURNAL OF CHROMATOGRAPHY, 1990, 498 (01) :169-178
[9]   NEW HIGH-SPEED COUNTERCURRENT CHROMATOGRAPH EQUIPPED WITH A PAIR OF SEPARATION COLUMNS CONNECTED IN SERIES [J].
ITO, Y ;
CHOU, FE .
JOURNAL OF CHROMATOGRAPHY, 1988, 454 :382-386
[10]   ANALYTICAL HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY WITH A COIL PLANET CENTRIFUGE [J].
ITO, Y ;
LEE, YW .
JOURNAL OF CHROMATOGRAPHY, 1987, 391 (01) :290-295