INTESTINAL HEMORRHAGE FROM EXPOSURE TO PULSED ULTRASOUND

被引:56
作者
DALECKI, D [1 ]
RAEMAN, CH [1 ]
CHILD, SZ [1 ]
CARSTENSEN, EL [1 ]
机构
[1] UNIV ROCHESTER,ROCHESTER CTR BIOMED ULTRASOUND,ROCHESTER,NY 14627
关键词
PULSED ULTRASOUND; INTESTINAL HEMORRHAGE; ULTRASOUND BIOEFFECT; MICE;
D O I
10.1016/0301-5629(95)00041-O
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Threshold exposures for producing intestinal hemorrhage in mice were determined using focused sources operating at 0.7, 1.1, 2.4 and 3.6 MHz, The choice of pulse length (10 mu s) and pulse repetition frequency (100 Hz) made the exposures diagnostically relevant, while at the same time, minimized possible thermal contributions to the mechanism of action of the ultrasound, Each animal was irradiated at four to five abdominal sites for 5 min per site, Suprathreshold lesions ranged from small petechiae to hemorrhagic regions extending 4 mm or more along the intestine, depending upon the exposure levels, Higher frequencies were less effective in producing intestinal hemorrhage than lower frequencies, Thermocouple measurements of temperature rise in the intestine during ultrasound exposure revealed temperature increments between 1 degrees and 2 degrees C at the highest exposure levels, The frequency dependence of the production of intestinal hemorrhage together with the observed limited heating is consistent with a cavitation-related mechanism of action of pulsed ultrasound.
引用
收藏
页码:1067 / 1072
页数:6
相关论文
共 16 条
  • [1] CAVITATION INDUCED BY ASYMMETRIC DISTORTED PULSES OF ULTRASOUND - THEORETICAL PREDICTIONS
    AYME, EJ
    CARSTENSEN, EL
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1989, 36 (01) : 32 - 40
  • [2] BAGGS R, 1995, IN PRESS ULTRASOUND
  • [3] BAILEY MR, 1994, J ACOUST SOC AM, V96, P3305
  • [4] LYSIS OF CELLS IN ELODEA LEAVES BY PULSED AND CONTINUOUS WAVE ULTRASOUND
    CARSTENSEN, EL
    CHILD, SZ
    CRANE, C
    MILLER, MW
    PARKER, KJ
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (02) : 167 - 173
  • [5] LUNG DAMAGE FROM EXPOSURE TO PULSED ULTRASOUND
    CHILD, SZ
    HARTMAN, CL
    SCHERY, LA
    CARSTENSEN, EL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (08) : 817 - 825
  • [6] EFFECTS OF ULTRASOUND ON DROSOPHILA .3. EXPOSURE OF LARVAE TO LOW-TEMPORAL-AVERAGE-INTENSITY, PULSED IRRADIATION
    CHILD, SZ
    CARSTENSEN, EL
    LAM, SK
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1981, 7 (02) : 167 - 173
  • [7] DALECKI D, 1995, IN PRESS ULTRASOUND
  • [8] DUNN F, 1977, ACUSTICA, V38, P58
  • [9] EFFECTS OF PULSED ULTRASOUND ON THE MOUSE NEONATE - HIND-LIMB PARALYSIS AND LUNG HEMORRHAGE
    FRIZZELL, LA
    CHEN, E
    LEE, C
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (01) : 53 - 63
  • [10] LEHMANN J F, 1953, Arch Phys Med Rehabil, V34, P86