GINGIVAL CREVICULAR BLOOD FOR ASSESSMENT OF BLOOD-GLUCOSE IN DIABETIC-PATIENTS

被引:29
|
作者
PARKER, RC
RAPLEY, JW
ISLEY, W
SPENCER, P
KILLOY, WJ
机构
[1] UNIV MISSOURI,SCH DENT,DEPT PERIODONT,650 E 25TH ST,KANSAS CITY,MO 64108
[2] TRUMAN MED CTR,DEPT MED,KANSAS CITY,MO
[3] UNIV MISSOURI,SCH DENT,DEPT ORAL BIOL,KANSAS CITY,MO 64108
关键词
GINGIVAL CREVICULAR FLUID ANALYSIS; BLOOD GLUCOSE ANALYSIS; DIABETES-MELLITUS;
D O I
10.1902/jop.1993.64.7.666
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
IN THIS STUDY 50 PATIENTs with diabetes mellitus had gingival crevicular blood from periodontal probing collected in small plastic pipettes. The pipettes transferred the crevicular blood to a non-wipe glucose self-monitoring instrument. At the same time, finger-stick capillary blood measurements were analyzed in the same glucose self-monitoring instrument, and venous blood was collected for measurement in a laboratory glucose analyzer. Each laboratory measurement was corrected from a serum glucose value to a whole blood glucose value by a function of the patient's hematocrit. This corrected glucose value allowed direct comparison of the laboratory measurement to the intraoral and finger-stick whole blood measurements. The patient blood glucose concentrations ranged from 59 mg/dl to 366 mg/dl. The gingival crevicular blood exhibited a correlation of r = 0.975 (P <.0001) to the corrected laboratory standard measurement, with a mean prediction error (bias) of -4.11 mg/dl and a root mean square error (precision) of 17.43 mg/dl. The finger-stick blood had a correlation of r = 0.983 (P <.0001) to the corrected laboratory standard, with a mean prediction error of 4.65 mg/dl and a root mean square error of 14.48 mg/dl. The American Diabetic Association recommends that the prediction error of blood glucose monitoring devices fall within 15% of the laboratory standard. Using this criterion 92% of the gingival crevicular measurements and 90% of the finger-puncture measurements fell within 15% of the laboratory value. The results suggest that gingival crevicular blood collected by a small plastic pipette and measured in a non-wipe glucose self-monitor is feasible for in-office blood glucose testing with measurements comparable to those obtained using the finger-puncture method.
引用
收藏
页码:666 / 672
页数:7
相关论文
共 50 条
  • [31] COMPARISON OF GLYCOSYLATED FIBRINOGEN, ALBUMIN, AND HEMOGLOBIN AS INDEXES OF BLOOD-GLUCOSE CONTROL IN DIABETIC-PATIENTS
    ARDAWI, MSM
    NASRAT, HN
    MIRA, SA
    FATANI, HH
    DIABETIC MEDICINE, 1990, 7 (09) : 819 - 824
  • [32] THE EFFECT OF BODY-WEIGHT LOSS ON BLOOD-GLUCOSE LEVELS IN INSTITUTIONALIZED DIABETIC-PATIENTS
    OSTERWEIL, D
    MAZORRA, L
    MARSHALL, CE
    MOORADIAN, AD
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1990, 38 (08) : A32 - A32
  • [33] SELF MONITORING OF BLOOD-GLUCOSE CONCENTRATIONS BY NON-INSULIN-DEPENDENT DIABETIC-PATIENTS
    TATTERSALL, R
    BRITISH MEDICAL JOURNAL, 1992, 305 (6863): : 1171 - 1172
  • [34] EFFECT OF ACARBOSE ON BLOOD-GLUCOSE PROFILE OF TOTALLY INSULIN-DEPENDENT DIABETIC-PATIENTS
    DAMOISEAUX, P
    BUYSSCHAERT, M
    KETELSLEGERS, JM
    HILLEBRAND, IS
    LAMBERT, AE
    ACTA CLINICA BELGICA, 1983, 38 (01): : 5 - 11
  • [35] THE CHALLENGE OF BLOOD-GLUCOSE MANAGEMENT IN DIABETIC-PATIENTS RECEIVING ENTERAL OR PARENTERAL-NUTRITION
    PETERS, AL
    DAVIDSON, MB
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1993, 17 (01) : 1 - 2
  • [36] BLOOD-GLUCOSE SELF MONITORING BY DIABETIC-PATIENTS, A NEW APPROACH TO IMPROVE METABOLIC CONTROL
    LEIDINGER, F
    JORGENS, V
    CHANTELAU, E
    BERCHTOLD, P
    BERGER, M
    FORTSCHRITTE DER MEDIZIN, 1980, 98 (28) : 1041 - 1044
  • [38] EFFECTS OF SELF-MONITORING OF BLOOD-GLUCOSE ON QUALITY OF LIFE IN ELDERLY DIABETIC-PATIENTS
    GILDEN, JL
    CASIA, C
    HENDRYX, M
    SINGH, SP
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1990, 38 (05) : 511 - 515
  • [39] LONG-TERM BLOOD-GLUCOSE REGULATIONS IN DIABETIC-PATIENTS WITH A WEARABLE ARTIFICIAL ENDOCRINE PANCREAS
    HASHIGUCHI, Y
    SAKAKIDA, M
    ICHINOSE, K
    NISHIDA, K
    UEHARA, M
    KISHIKAWA, H
    SHICHIRI, M
    DIABETOLOGIA, 1992, 35 : A205 - A205
  • [40] ONE YEAR OF HOME BLOOD-GLUCOSE MONITORING IN 80 INSULIN-REQUIRING DIABETIC-PATIENTS
    LOUIS, J
    KOLOPP, M
    POINTEL, JP
    DROUIN, P
    DEBRY, G
    DIABETOLOGIA, 1982, 23 (02) : 184 - 184