GINGIVAL CREVICULAR BLOOD FOR ASSESSMENT OF BLOOD-GLUCOSE IN DIABETIC-PATIENTS

被引:29
|
作者
PARKER, RC
RAPLEY, JW
ISLEY, W
SPENCER, P
KILLOY, WJ
机构
[1] UNIV MISSOURI,SCH DENT,DEPT PERIODONT,650 E 25TH ST,KANSAS CITY,MO 64108
[2] TRUMAN MED CTR,DEPT MED,KANSAS CITY,MO
[3] UNIV MISSOURI,SCH DENT,DEPT ORAL BIOL,KANSAS CITY,MO 64108
关键词
GINGIVAL CREVICULAR FLUID ANALYSIS; BLOOD GLUCOSE ANALYSIS; DIABETES-MELLITUS;
D O I
10.1902/jop.1993.64.7.666
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
IN THIS STUDY 50 PATIENTs with diabetes mellitus had gingival crevicular blood from periodontal probing collected in small plastic pipettes. The pipettes transferred the crevicular blood to a non-wipe glucose self-monitoring instrument. At the same time, finger-stick capillary blood measurements were analyzed in the same glucose self-monitoring instrument, and venous blood was collected for measurement in a laboratory glucose analyzer. Each laboratory measurement was corrected from a serum glucose value to a whole blood glucose value by a function of the patient's hematocrit. This corrected glucose value allowed direct comparison of the laboratory measurement to the intraoral and finger-stick whole blood measurements. The patient blood glucose concentrations ranged from 59 mg/dl to 366 mg/dl. The gingival crevicular blood exhibited a correlation of r = 0.975 (P <.0001) to the corrected laboratory standard measurement, with a mean prediction error (bias) of -4.11 mg/dl and a root mean square error (precision) of 17.43 mg/dl. The finger-stick blood had a correlation of r = 0.983 (P <.0001) to the corrected laboratory standard, with a mean prediction error of 4.65 mg/dl and a root mean square error of 14.48 mg/dl. The American Diabetic Association recommends that the prediction error of blood glucose monitoring devices fall within 15% of the laboratory standard. Using this criterion 92% of the gingival crevicular measurements and 90% of the finger-puncture measurements fell within 15% of the laboratory value. The results suggest that gingival crevicular blood collected by a small plastic pipette and measured in a non-wipe glucose self-monitor is feasible for in-office blood glucose testing with measurements comparable to those obtained using the finger-puncture method.
引用
收藏
页码:666 / 672
页数:7
相关论文
共 50 条
  • [21] PERIOPERATIVE CONTROL OF BLOOD-GLUCOSE IN DIABETIC-PATIENTS - A 2-STEP PROTOCOL
    MEYERS, EF
    ALBERTS, D
    GORDON, MO
    DIABETES CARE, 1986, 9 (01) : 40 - 45
  • [22] PSYCHOLOGICAL STRESS AND BLOOD-GLUCOSE REGULATION IN TYPE-I DIABETIC-PATIENTS
    HALFORD, WK
    CUDDIHY, S
    MORTIMER, RH
    HEALTH PSYCHOLOGY, 1990, 9 (05) : 516 - 528
  • [23] EFFECT OF BLOOD-GLUCOSE CONTROL ON PERIPHERAL-NERVE FUNCTION IN DIABETIC-PATIENTS
    SERVICE, FJ
    DAUBE, JR
    OBRIEN, PC
    ZIMMERMAN, BR
    SWANSON, CJ
    BRENNAN, MD
    DYCK, PJ
    MAYO CLINIC PROCEEDINGS, 1983, 58 (05) : 283 - 289
  • [24] TIME-SERIES ANALYSIS AND CONTROL OF BLOOD-GLUCOSE LEVELS IN DIABETIC-PATIENTS
    DEUTSCH, T
    LEHMANN, ED
    CARSON, ER
    ROUDSARI, AV
    HOPKINS, KD
    SONKSEN, PH
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1994, 41 (3-4) : 167 - 182
  • [25] TUBULAR REABSORPTION OF GLUCOSE IN QUANTIFYING THE RELATION BETWEEN BLOOD-GLUCOSE AND URINARY GLUCOSE EXCRETION IN DIABETIC-PATIENTS
    ERKELENS, DW
    DULLAART, R
    PEUKER, N
    NETHERLANDS JOURNAL OF MEDICINE, 1983, 26 (01): : 1 - 9
  • [26] Evaluation of Blood Glucose Level using Gingival Crevicular Blood in Diabetic and Non-diabetic Patients: A Non-Randomized Study
    Rathan, R. T. Reethika
    Fenn, Saramma M.
    Mohan, Karthik R.
    Thangavelu, Ravikumar P.
    Gokulraj, Sabitha
    Appusamy, Kumar
    JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY, 2023, 35 (02) : 217 - 221
  • [27] SELF-MONITORING OF BLOOD-GLUCOSE IN OVERWEIGHT TYPE-2 DIABETIC-PATIENTS
    MUCHMORE, DB
    SPRINGER, J
    MILLER, M
    ACTA DIABETOLOGICA, 1994, 31 (04) : 215 - 219
  • [28] INCREASED FRUCTOSE-LYSINE OF NAIL PROTEIN AND BLOOD-GLUCOSE CONTROL IN DIABETIC-PATIENTS
    OIMOMI, M
    NISHIMOTO, S
    KITAMURA, Y
    MATSUMOTO, S
    HATANAKA, H
    BABA, S
    HORMONE AND METABOLIC RESEARCH, 1986, 18 (12) : 827 - 829
  • [29] THE SEPARATE INFLUENCE OF DIETARY FIBER AND DIGESTIBLE CARBOHYDRATES ON BLOOD-GLUCOSE CONTROL IN DIABETIC-PATIENTS
    RIVELLESE, A
    PERROTTI, N
    GENOVESE, S
    SANTORO, D
    GIACCO, A
    RICCARDI, G
    DIABETOLOGIA, 1982, 23 (02) : 195 - 195
  • [30] INCREASED FRUCTOSE-LYSINE OF HAIR PROTEIN AND BLOOD-GLUCOSE CONTROL IN DIABETIC-PATIENTS
    OIMOMI, M
    MAEDA, Y
    HATA, F
    KITAMURA, Y
    MATSUMOTO, S
    HATANAKA, H
    BABA, S
    HORMONE AND METABOLIC RESEARCH, 1988, 20 (10) : 654 - 655