GINGIVAL CREVICULAR BLOOD FOR ASSESSMENT OF BLOOD-GLUCOSE IN DIABETIC-PATIENTS

被引:29
|
作者
PARKER, RC
RAPLEY, JW
ISLEY, W
SPENCER, P
KILLOY, WJ
机构
[1] UNIV MISSOURI,SCH DENT,DEPT PERIODONT,650 E 25TH ST,KANSAS CITY,MO 64108
[2] TRUMAN MED CTR,DEPT MED,KANSAS CITY,MO
[3] UNIV MISSOURI,SCH DENT,DEPT ORAL BIOL,KANSAS CITY,MO 64108
关键词
GINGIVAL CREVICULAR FLUID ANALYSIS; BLOOD GLUCOSE ANALYSIS; DIABETES-MELLITUS;
D O I
10.1902/jop.1993.64.7.666
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
IN THIS STUDY 50 PATIENTs with diabetes mellitus had gingival crevicular blood from periodontal probing collected in small plastic pipettes. The pipettes transferred the crevicular blood to a non-wipe glucose self-monitoring instrument. At the same time, finger-stick capillary blood measurements were analyzed in the same glucose self-monitoring instrument, and venous blood was collected for measurement in a laboratory glucose analyzer. Each laboratory measurement was corrected from a serum glucose value to a whole blood glucose value by a function of the patient's hematocrit. This corrected glucose value allowed direct comparison of the laboratory measurement to the intraoral and finger-stick whole blood measurements. The patient blood glucose concentrations ranged from 59 mg/dl to 366 mg/dl. The gingival crevicular blood exhibited a correlation of r = 0.975 (P <.0001) to the corrected laboratory standard measurement, with a mean prediction error (bias) of -4.11 mg/dl and a root mean square error (precision) of 17.43 mg/dl. The finger-stick blood had a correlation of r = 0.983 (P <.0001) to the corrected laboratory standard, with a mean prediction error of 4.65 mg/dl and a root mean square error of 14.48 mg/dl. The American Diabetic Association recommends that the prediction error of blood glucose monitoring devices fall within 15% of the laboratory standard. Using this criterion 92% of the gingival crevicular measurements and 90% of the finger-puncture measurements fell within 15% of the laboratory value. The results suggest that gingival crevicular blood collected by a small plastic pipette and measured in a non-wipe glucose self-monitor is feasible for in-office blood glucose testing with measurements comparable to those obtained using the finger-puncture method.
引用
收藏
页码:666 / 672
页数:7
相关论文
共 50 条
  • [1] HOME MONITORING OF BLOOD-GLUCOSE BY DIABETIC-PATIENTS
    SONKSEN, PH
    ACTA ENDOCRINOLOGICA, 1980, 94 : 145 - 155
  • [2] Assessment of Blood Glucose Using Gingival Crevicular Blood in Diabetic and Non-Diabetic Patients: A Chair Side Method
    Kaur, Harmanpreet
    Singh, Bhawanpreet
    Sharma, Anshu
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2013, 7 (12) : 3066 - 3069
  • [3] SELF-MONITORING OF BLOOD-GLUCOSE BY DIABETIC-PATIENTS
    RUBIN, AL
    BERNSTEIN, RI
    WESTERN JOURNAL OF MEDICINE, 1981, 135 (03): : 244 - 244
  • [4] THE RELIABILITY OF SELF BLOOD-GLUCOSE MONITORING IN ELDERLY DIABETIC-PATIENTS
    BERNBAUM, M
    ALBERT, SG
    MCGINNIS, J
    BRUSCA, S
    MOORADIAN, AD
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1994, 42 (07) : 779 - 781
  • [5] BLOOD-GLUCOSE SYMPTOM BELIEFS OF DIABETIC-PATIENTS - ACCURACY AND IMPLICATIONS
    GONDERFREDERICK, LA
    COX, DJ
    BOBBITT, SA
    PENNEBAKER, JW
    HEALTH PSYCHOLOGY, 1986, 5 (04) : 327 - 341
  • [6] THE INFLUENCE OF PENBUTOLOL AND FUROSEMIDE ON BLOOD-GLUCOSE LEVELS IN DIABETIC-PATIENTS
    SCHULZ, GHA
    BEYER, J
    HENRICH, J
    DIABETES, 1986, 35 : A146 - A146
  • [7] GLYCOSYLATED HEMOGLOBIN AND BLOOD-GLUCOSE LEVELS IN LIBYAN DIABETIC-PATIENTS
    RAO, GMM
    MORGHOM, LO
    ABUKHRIS, AA
    MANSORI, SS
    ALPHGIH, FA
    RAGALE, LY
    TROPICAL AND GEOGRAPHICAL MEDICINE, 1986, 38 (04): : 391 - 397
  • [8] INCREASE OF BLOOD-GLUCOSE CONCENTRATIONS IN DIABETIC-PATIENTS WITH GLUCAGON EYEDROPS
    CHUANG, LM
    WU, HP
    CHIOU, GCY
    ACTA PHARMACOLOGICA SINICA, 1992, 13 (03) : 193 - 197
  • [9] MODEL FOLLOWING CONTROL-SYSTEM OF THE BLOOD-GLUCOSE FOR DIABETIC-PATIENTS
    YAMADA, A
    MACHIYAMA, E
    KABEI, N
    SAKURAI, Y
    KIKUCHI, M
    KONDO, K
    HARA, Y
    ARTIFICIAL ORGANS, 1981, 5 (03) : 316 - 316
  • [10] CIRCADIAN-RHYTHMS IN BLOOD-GLUCOSE AND URINARY POTASSIUM OF DIABETIC-PATIENTS
    GHATA, J
    REINBERG, A
    CHRONOBIOLOGIA, 1978, 5 (02) : 205 - 205