A Study of NPSH Required Performance Improvement for a Industrial Vertical Pump

被引:1
作者
Chung, Kyung-Nam
Park, Jong-Hwoo
Kim, Yong-Kyun
Kim, Hae-Cheon
机构
关键词
Vertical Pump; CFD; DOE; Pump Design; Efficiency; NPSH Required;
D O I
10.3795/KSME-B.2009.33.11.909
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this paper, a study of performance improvement for a centrifugal vertical pump having specific speed of 330 is introduced. The existing model has high efficiency but needs better NPSH required performance. Such that new pump model is designed to obtain larger suction specific speed. 6 design parameters considered to affect pump performance are selected for impeller design. Key design parameters are investigated using by design of experiments and CFD, and impeller inlet diameter is increased to get better suction performance. The amount of inlet diameter increase is determined by using cavitation analysis. The results show that new design model has higher efficiency and better NPSH required performance than the existing model.
引用
收藏
页码:909 / 915
页数:7
相关论文
共 9 条
  • [1] AEA Technology, 2000, CFX BLADEGEN V4 1
  • [2] [Anonymous], 2006, CFX 11 ANSYS CFX SOL
  • [3] Bakir F, 2003, 5 INT S CAV
  • [4] 김준형, 2008, [The KSFM Journal of Fluid Machinery, 한국유체기계학회 논문집], V11, P18
  • [5] Chung K. N, 2002, FEDSM200231180 ASME
  • [6] Chung K. N., 2006, KFMA ANN M 2006, p225~266
  • [7] Meyers R.H., 1995, RESPONSE SURFACE MET
  • [8] Minitab Inc, 2000, MINITAB V13
  • [9] Stepanoff A. J, 1957, CENTRIFUGAL AXIAL FL, p75~136