摘要
The objective of the present study was the development of a new calibration standard for the laser-Doppler perfusion monitors. The beat frequency spectrum obtained from a solution of latex spheres undergoing Brownian motion was compared to that obtained from a porous polyethylene material containing the same solution. The mixture of static and dynamic scattering events in the latter case was expected to produce a spectrum similar to that obtained in the real human tissue. The results obtained demonstrate clearly the difference between the signals recorded from the commonly used motility standard which are the result of multiple Doppler shifting and homodyne mixing, and those generated from our enhanced model which predominantly result from single Doppler shifting and heterodyne mixing. (C) 1995 American Institute of Physics.
引用
收藏
页码:5169 / 5173
页数:5
相关论文
共 50 条
  • [31] THE SIGNIFICANCE OF PROBE DESIGN IN EVALUATION OF COLONIC PERFUSION WITH LASER-DOPPLER FLOWMETRY
    KROHGSORENSEN, K
    LINE, PD
    KVERNEBO, K
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1993, 28 (05) : 381 - 386
  • [32] Age effects on laser-doppler perfusion responses of men to forearm heat
    DeLeon, A
    Smith, J
    Mayrovitz, HN
    FASEB JOURNAL, 1998, 12 (04): : A8 - A8
  • [33] VELOCITY PROFILES IN ANNULAR PERFUSION CHAMBER MEASURED BY LASER-DOPPLER VELOCIMETRY
    AARTS, PAMM
    VANBROEK, JATM
    KUIKEN, GDC
    SIXMA, JJ
    HEETHAAR, RM
    JOURNAL OF BIOMECHANICS, 1984, 17 (01) : 61 - 63
  • [34] DOES LASER-DOPPLER FLOWMETRY PROVIDE A QUANTITATIVE MEASURE OF HEPATIC PERFUSION
    WHEATLEY, AM
    AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (05): : G960 - G961
  • [35] LASER-DOPPLER FLOWMETRY
    OBERG, PA
    CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 1990, 18 (02) : 125 - 163
  • [36] CALIBRATION OF LASER-DOPPLER FLOWMETRY FOR MEASUREMENT OF GINGIVAL BLOOD-FLOW
    SASANO, T
    SHOJI, N
    KURIWADA, S
    SANJO, D
    JOURNAL OF PERIODONTAL RESEARCH, 1995, 30 (04) : 298 - 301
  • [37] OPTIMUM SEEDING PARTICLES FOR SUCCESSFUL LASER-DOPPLER VELOCIMETER MEASUREMENTS
    IKEDA, Y
    NISHIGAKI, M
    IPPOMMATSU, M
    NAKAJIMA, T
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 1994, 11 (02) : 127 - 132
  • [38] LASER-DOPPLER VELOCITY MEASUREMENTS OF SWIRLING FLOWS WITH UPSTREAM INFLUENCE
    ORLOFF, KL
    BOSSEL, HH
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (11): : 1331 - &
  • [40] Differential laser-Doppler vibrometry for airborne vibration measurements with drones
    Schewe M.
    Ismail M.A.A.
    Rembe C.
    Technisches Messen, 2021, 88 (S1): : S42 - S47