Management of surgical instruments with radio frequency identification tags A 27-month in hospital trial

被引:15
作者
Kusuda, Kaori [1 ]
Yamashita, Kazuhiko [2 ]
Ohnishi, Akiko [3 ]
Tanaka, Kiyohito [4 ]
Komino, Masaru [5 ]
Honda, Hiroshi [6 ]
Tanaka, Shinichi [7 ]
Okubo, Takashi [8 ]
Tripette, Julien [9 ,10 ]
Ohta, Yuji [11 ]
机构
[1] Ochanomizu Univ, Grad Div Life Sci, Dept Human Environm Sci, Tokyo 112, Japan
[2] Tokyo Healthcare Univ, Fac Healthcare, Div Healthcare Informat, Tokyo, Japan
[3] Kyoto Second Red Cross Hosp, Dept Nurse, Kyoto, Japan
[4] Kyoto Second Red Cross Hosp, Dept Gastroenterol, Kyoto, Japan
[5] Saiseikai Kurihashi Hosp, Saiseikai Imperial Gift Fdn Inc, Social Welf Org, Div Infect Control, Saitama, Japan
[6] Saiseikai Kurihashi Hosp, Saiseikai Imperial Gift Fdn Inc, Social Welf Org, Saitama, Japan
[7] St Marianna Univ, Sch Med, Div Infect Control, Yokohama, Kanagawa, Japan
[8] Tokyo Healthcare Univ, Postgrad Sch, Fac Healthcare, Div Infect Prevent & Control, Tokyo, Japan
[9] Ochanomizu Univ, Dept Human & Environm Sci, Tokyo 112, Japan
[10] Ochanomizu Univ, Leading Grad Sch, Promot Ctr, Tokyo 112, Japan
[11] Ochanomizu Univ, Fac Core Res, Div Nat Sci, Tokyo 112, Japan
关键词
Performance measurement; Patient safety; Learning; Management;
D O I
10.1108/IJHCQA-03-2015-0034
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose - To prevent malpractices, medical staff has adopted inventory time-outs and/or checklists. Accurate inventory and maintenance of surgical instruments decreases the risk of operating room miscounting and malfunction. In our previous study, an individual management of surgical instruments was accomplished using Radio Frequency Identification (RFID) tags. The purpose of this paper is to evaluate a new management method of RFID-tagged instruments. Design/methodology/approach - The management system of RFID-tagged surgical instruments was used for 27 months in clinical areas. In total, 13 study participants assembled surgical trays in the central sterile supply department. Findings - While using the management system, trays were assembled 94 times. During this period, no assembly errors occurred. An instrument malfunction had occurred after the 19th, 56th, and 73th uses, no malfunction caused by the RFID tags, and usage history had been recorded. Additionally, the time it took to assemble surgical trays was recorded, and the long-term usability of the management system was evaluated. Originality/value - The system could record the number of uses and the defective history of each surgical instrument. In addition, the history of the frequency of instruments being transferred from one tray to another was recorded. The results suggest that our system can be used to manage instruments safely. Additionally, the management system was acquired of the learning effect and the usability on daily maintenance. This finding suggests that the management system examined here ensures surgical instrument and tray assembly quality.
引用
收藏
页码:236 / 247
页数:12
相关论文
共 25 条
  • [1] Prospective evaluation of 100 robotic-assisted unilateral adrenalectomies
    Brunaud, Laurent
    Ayav, Ahmet
    Zarnegar, Rasa
    Rouers, Anthony
    Klein, Marc
    Boissel, Patrick
    Bresler, Laurent
    [J]. SURGERY, 2008, 144 (06) : 995 - 1001
  • [2] Managing the prevention of retained surgical instruments - What is the value of counting?
    Egorova, Natalia N.
    Moskowitz, Alan
    Gelijns, Annetine
    Weinberg, Alan
    Curty, James
    Rabin-Fastman, Barbara
    Kaplan, Harold
    Cooper, Mary
    Fowler, Dennis
    Emond, Jean C.
    Greco, Giampaolo
    [J]. ANNALS OF SURGERY, 2008, 247 (01) : 13 - 18
  • [3] A method to characterize the learning curve for performance of a fundamental laparoscopic simulator task: Defining "learning plateau" and "learning rate"
    Feldman, Liane S.
    Cao, Jiguo
    Andalib, Amin
    Fraser, Shannon
    Fried, Gerald M.
    [J]. SURGERY, 2009, 146 (02) : 381 - 386
  • [4] Risk factors for retained instruments and sponges after surgery
    Gawande, AA
    Studdert, DM
    Orav, EJ
    Brennan, TA
    Zinner, MJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (03) : 229 - 235
  • [5] Goldberg Judith L, 2012, AORN J, V95, P205, DOI 10.1016/j.aorn.2011.11.010
  • [6] Quantifying nursing workflow in medication administration
    Keohane, Carol A.
    Bane, Anne D.
    Featherstone, Erica
    Hayes, Judy
    Woolf, Seth
    Hurley, Ann
    Bates, David W.
    Gandhi, Teja K.
    Poon, Eric G.
    [J]. JOURNAL OF NURSING ADMINISTRATION, 2008, 38 (01): : 19 - 26
  • [7] RFID in the healthcare supply chain: usage and application
    Kumar, Sameer
    Swanson, Eric
    Thuy Tran
    [J]. INTERNATIONAL JOURNAL OF HEALTH CARE QUALITY ASSURANCE, 2009, 22 (01) : 67 - +
  • [8] Kusuda K., 2012, JAPANESE SOC MED INS, V82, P249
  • [9] Retained foreign bodies after surgery
    Lincourt, Amy E.
    Harrell, Andrew
    Cristiano, Joseph
    Sechrist, Cathy
    Kercher, Kent
    Heniford, B. Todd
    [J]. JOURNAL OF SURGICAL RESEARCH, 2007, 138 (02) : 170 - 174
  • [10] Initial clinical evaluation of a handheld device for detecting retained surgical gauze sponges using radiofrequency identification technology
    Macario, Alex
    Morris, Dean
    Morris, Sharon
    [J]. ARCHIVES OF SURGERY, 2006, 141 (07) : 659 - 662