DETERMINATION OF 4,4'-METHYLENEDIANILINE IN HYDROLYZED HUMAN URINE BY MICRO LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION

被引:13
作者
BRUNMARK, P
PERSSON, P
SKARPING, G
机构
[1] Department of Occupational and Environmental Medicine, University Hospital
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1992年 / 579卷 / 02期
关键词
D O I
10.1016/0378-4347(92)80403-D
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
4,4'-Methylenedianiline was determined in human urine by micro liquid chromatography with ultraviolet detection. The combination of a thorough work-up and the high mass sensitivity of micro liquid chromatography gave the method very high sensitivity. Derivatization with pentafluoropropionic anhydride enhanced the resolution of the 4,4'-dimethylenedianiline peak. The detection limit, defined as blank plus three times the standard deviation of the blank, was 2 nmol/l of urine, for 10-mu-l injection volumes. The detection limit, defined as three times the noise, was about ten times better. The within- and between-assay coefficients of variation were 4 and 6%, respectively, for samples containing 40 nmol/l. The method was applied for the monitoring of excreted 4,4'-methylenedianiline in urine, during epicutaneous skin hypersensitivity testing (patch testing).
引用
收藏
页码:350 / 354
页数:5
相关论文
共 13 条
[1]   DETERMINATION OF TOLUENE DIISOCYANATE IN AIR USING MICRO LIQUID-CHROMATOGRAPHY WITH UV-DETECTION [J].
BRUNMARK, P ;
DALENE, M ;
SANGO, C ;
SKARPING, G ;
ERLANDSSON, P ;
DEWAELE, C .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1991, 3 (04) :371-375
[2]  
CHERVET JP, 1991, LC GC INT, V4, P11
[3]  
COCKER J, 1986, BRIT J IND MED, V43, P620
[4]   STUDY OF MICRO-HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. DEVELOPMENT OF TECHNIQUE FOR MINIATURIZATION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ISHII, D ;
ASAI, K ;
HIBI, K ;
JONOKUCHI, T ;
NAGAYA, M .
JOURNAL OF CHROMATOGRAPHY, 1977, 144 (02) :157-168
[5]  
KUSTERS E, 1992, BRIT J IND MED, V49, P72
[6]  
LEVINE MJ, 1983, CONTACT DERMATOL, V9, P448
[7]   INDUSTRIAL OUTBREAK OF TOXIC HEPATITIS DUE TO METHYLENEDIANILINE [J].
MCGILL, DB ;
MOTTO, JD .
NEW ENGLAND JOURNAL OF MEDICINE, 1974, 291 (06) :278-282
[8]  
MILLER JC, 1988, STATISTICS ANAL CHEM
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF 4,4'-METHYLENEDIANILINE IN HUMAN URINE [J].
PETERSON, JC ;
ESTIVA, EC ;
LYTTLE, DS ;
HARRIS, RM .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 564 (01) :205-212
[10]   CHROMATOGRAPHIC DETERMINATION OF AMINES IN BIOLOGICAL-FLUIDS WITH SPECIAL REFERENCE TO THE BIOLOGICAL MONITORING OF ISOCYANATES AND AMINES .3. DETERMINATION OF 4,4'-METHYLENEDIANILINE IN HYDROLYZED HUMAN-URINE USING DERIVATIZATION AND CAPILLARY GAS-CHROMATOGRAPHY WITH SELECTED ION MONITORING [J].
TILJANDER, A ;
SKARPING, G ;
DALENE, M .
JOURNAL OF CHROMATOGRAPHY, 1989, 479 (01) :145-152