A Simulation of Claus Process Via Aspen Hysys for Sulfur Recovery

被引:5
作者
Nabgan, Walid [1 ]
Abdullah, Tuan Amran Tuan [1 ]
Nabgan, Bahador [1 ]
Ripin, Adnan [1 ]
Bin Kidam, Kamarizan [2 ]
Saeh, Ibrahim [3 ]
Moghadamian, Kamal [4 ]
机构
[1] Univ Teknol Malaysia, Inst Future Energy, Ctr Hydrogen Energy, Skudai 81310, Johor, Malaysia
[2] Univ Teknol Malaysia, Fac Chem & Energy Engn, Dept Chem Engn, Skudai 81310, Johor, Malaysia
[3] Univ Teknol Malaysia, Fac Elect Engn, Dept Elect Power Engn, Skudai 81310, Johor, Malaysia
[4] Islamic Azad Univ Mahshahr, Mahshahr, Iran
来源
CHEMICAL PRODUCT AND PROCESS MODELING | 2016年 / 11卷 / 04期
关键词
simulation; Claus process; aspen hysys; sulfur Recovery;
D O I
10.1515/cppm-2016-0019
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In refineries, due to the environmental pollutions, sulfur content in petroleum need be reduced. The incineration process is used for sulfur recovery system which is not friendly process to the environment and needs high temperature. This actual process exhaust high amount of SO2 from the incinerator stack to the environment. The Claus process is the best method to recover sulfur from acid gases that contain hydrogen sulfide. The particular reaction for sulfur removal from sour gas is hydrogen sulfide (H2S) sulfur dioxide (SO2) reformation (2H(2)S + O-2= S-2 + 2H(2)O). The aim of this study is to get a simulation that is suitable for the characterization of sulfur recovery units. The experimental design for this study was collected from a petroleum refinery located in Iran. This experimental relation supports us to gather with definite consistency that is normally not available online for such process. Aspen HYSYS v8.8 software was used to simulate the Claus process by reactors and component splitters. The result shows the complete conversion of sour gas to product. The simulation protects the environmental impact by SO2 emission. This behavior can be reproduced by this HYSYS design very well. It was found that the BURNAIR feed composition and molar flow is the only factors which can affect the hydrogen sulfide conversion. The sulfur mole fraction increased only in the range of 0.94 to 0.98 by increasing N-2 from 0.7 to 0.9.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 20 条
[1]  
Ahmadi F., 2012, ASSESSING PERFORMANC
[2]  
Aliabad H. Zare, 2009, INT J CHEM MOL ENG, V3, P50
[3]   Environmental impact of a coal combustion-desulphurisation plant:: Abatement capacity of desulphurisation process and environmental characterisation of combustion by-products [J].
Alvarez-Ayuso, E. ;
Querol, X. ;
Tomas, A. .
CHEMOSPHERE, 2006, 65 (11) :2009-2017
[4]   Inhibition and sensitization of fuel oxidation by SO2 [J].
Alzueta, MU ;
Bilbao, R ;
Glarborg, P .
COMBUSTION AND FLAME, 2001, 127 (04) :2234-2251
[5]   The pharmacology, toxicology, and medical treatment of sulphur mustard poisoning [J].
Balali-Mood, M ;
Hefazi, M .
FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2005, 19 (03) :297-315
[6]  
Dyment J, 2015, ACID GAS CLEANING US
[7]  
Glarborg P, 1996, INT J CHEM KINET, V28, P773, DOI 10.1002/(SICI)1097-4601(1996)28:10<773::AID-KIN8>3.0.CO
[8]  
2-K
[9]   Xylene and H2S destruction in high temperature flames under Claus condition [J].
Ibrahim, S. ;
Gupta, A. K. ;
Al Shoaibi, A. .
APPLIED ENERGY, 2015, 154 :352-360
[10]   Medical aspects of sulphur mustard poisoning [J].
Kehe, K ;
Szinicz, L .
TOXICOLOGY, 2005, 214 (03) :198-209