APPARATUS FOR CONTINUOUSLY MONITORING HYDROGEN GAS DISSOLVED IN TRANSFORMER OIL

被引:12
作者
TSUKIOKA, H [1 ]
SUGAWARA, K [1 ]
MORI, E [1 ]
机构
[1] HITACHI LTD,KOKUBU WORKS,HITACHI,JAPAN
来源
IEEE TRANSACTIONS ON ELECTRICAL INSULATION | 1981年 / 16卷 / 06期
关键词
D O I
10.1109/TEI.1981.298381
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
引用
收藏
页码:502 / 509
页数:8
相关论文
共 50 条
[41]   Forecasting model based on BIC and SVRM for dissolved gas in transformer oil [J].
Zheng, Yuanbing ;
Chen, Weigen ;
Li, Jian ;
Du, Lin ;
Sun, Caixin .
Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2011, 31 (09) :46-49
[42]   Determination of the Ostwald coefficient of dissolved gases in transformer oil with gas chromatography [J].
Zhao, JH ;
Wang, HL ;
Yang, P ;
Guan, YF .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (04) :471-474
[43]   Research on spectrum absorption detect fault gas dissolved in transformer oil [J].
Meng, Z ;
Fan, FJ .
ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 8, 2005, :221-224
[44]   Prediction for Dissolved Gas in Power Transformer Oil Based On TCN and GCN [J].
Luo, Diansheng ;
Fang, Jie ;
He, Hongying ;
Lee, Wei-Jen ;
Zhang, Zhenyuan ;
Zai, Hongtao ;
Chen, Wengang ;
Zhang, Ke .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (06) :7818-7826
[45]   Transformer Health Monitoring Using Dissolved Gas Analysis: A Technical Brief [J].
Walker, Cody ;
Al Rashdan, Ahmad ;
Agarwal, Vivek .
INTERNATIONAL JOURNAL OF PROGNOSTICS AND HEALTH MANAGEMENT, 2022, 13 (02)
[46]   Transformer reliability enhancement using online dissolved gas monitoring and diagnostics [J].
Arshad, M ;
Islam, SM .
IPEC 2003: Proceedings of the 6th International Power Engineering Conference, Vols 1 and 2, 2003, :369-374
[47]   Interpretable Transformer Fault Diagnosis Based on SHAP Value and Dissolved Gas Analysis of Transformer Oil [J].
Liao C. ;
Yang J. ;
Qiu Z. ;
Hu X. ;
Zeng Q. ;
Huang Z. .
Dianwang Jishu/Power System Technology, 2024, 48 (04) :1752-1761
[48]   Dissolved gas in transformer oil forecasting for transformer fault evaluation based on HATT-RLSTM [J].
Zhong, Mingwei ;
Cao, Yunfei ;
He, Guanglin ;
Feng, Lutao ;
Tan, Zhichao ;
Mo, Wenjun ;
Fan, Jingmin .
ELECTRIC POWER SYSTEMS RESEARCH, 2023, 221
[49]   A TIME SERIES ANALYSIS BASED DATA TENDENCY PREDICTION METHOD FOR DISSOLVED GAS PRODUCTION MONITORING IN POWER TRANSFORMER OIL [J].
Zhang Wei ;
Wu Rongrong ;
Pu Jinyu ;
Deng Yurong .
UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2019, 81 (01) :99-108
[50]   Dissolved hydrogen measurement with palladium-silver FBG sensor in transformer oil [J].
Song, Hong-tu ;
Ma, Guo-ming ;
Jiang, Jun ;
Li, Cheng-rong ;
Luo, Ying-ting ;
Wang, Hong-bin .
2015 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2015, :73-76