FIRST RESULTS FROM THE HIGH-RESOLUTION XUV UNDULATOR BEAMLINE BW3 AT HASYLAB

被引:101
作者
LARSSON, CUS
BEUTLER, A
BJORNEHOLM, O
FEDERMANN, F
HAHN, U
RIECK, A
VERBIN, S
MOLLER, T
机构
[1] DESY,HASYLAB,D-22603 HAMBURG,GERMANY
[2] UNIV HAMBURG,INST EXPTL PHYS 2,D-22761 HAMBURG,GERMANY
关键词
D O I
10.1016/0168-9002(94)91133-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Initial results from the XUV undulator beamline at the 4.5 GeV storage ring DORIS are reported. The beamline consists of three different undulators mounted on a revolver type device and a modified SX-700 plane grating monochromator with a spherical focusing mirror. It covers the spectral range from 50-2000 eV with excellent spectral resolution and high photon flux. In the energy range 400 eV to 1 keV a spectral resolution estimated to 4500-9000 is obtained which is slightly better than the best values previously reported. In the energy range 50-1700 eV the photon flux is of the order of 10(11)-10(13)/s for a resolving power of a thousand normalized to a ring current of 100 mA. A study of the photofragmentation of H2O following K-shell excitation energetically close to the oxygen K-edge at similar to 540 eV demonstrates the excellent performance of the beamline, in particular for the investigation of secondary processes where a high flux is necessary.
引用
收藏
页码:603 / 608
页数:6
相关论文
共 26 条
[1]   PERFORMANCE OF THE DRAGON SOFT-X-RAY BEAMLINE [J].
CHEN, CT ;
SETTE, F .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1616-1621
[2]   CONCEPT AND DESIGN PROCEDURE FOR CYLINDRICAL ELEMENT MONOCHROMATORS FOR SYNCHROTRON RADIATION [J].
CHEN, CT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 256 (03) :595-604
[3]   OPTIMIZATION OF UNDULATORS FOR A SX-700 INSTRUMENT - FINITE-ELEMENT COUPLED TO RAY TRACING [J].
DECASTRO, ARB ;
REININGER, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1317-1320
[4]  
DECASTRO ARB, 1991, NUCL INSTRUM METH A, V207, P135
[5]   GRAZING INCIDENCE VACUUM ULTRAVIOLET MONOCHROMATOR WITH FIXED EXIT SLIT [J].
DIETRICH, H ;
KUNZ, C .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (03) :434-&
[6]   PERFORMANCE OF THE HIGH-RESOLUTION SX700/II MONOCHROMATOR [J].
DOMKE, M ;
MANDEL, T ;
PUSCHMANN, A ;
XUE, C ;
SHIRLEY, DA ;
KAINDL, G ;
PETERSEN, H ;
KUSKE, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :80-89
[7]  
FEDERMANN F, IN PRESS
[8]  
FEDERMANN F, IN PRESS CHEM PHYS L
[9]   VIBRATIONAL AND LIFETIME LINE BROADENINGS IN ESCA [J].
GELIUS, U ;
SVENSSON, S ;
SIEGBAHN, H ;
BASILIER, E ;
FAXALV, A ;
SIEGBAHN, K .
CHEMICAL PHYSICS LETTERS, 1974, 28 (01) :1-7
[10]  
GURTLER P, COMMUNICATION