FUTURE-PROSPECTS OF XAFS RESEARCHES USING HIGH BRILLIANCE PHOTON SOURCES

被引:11
作者
OYANAGI, H
机构
[1] Electrotechnical Laboratory, Tsukuba, 305, Umezono
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 1993年 / 32卷
关键词
XAFS; MULTIPOLE WIGGLER; INSERTION DEVICE; QUICK SCAN; HIGH BRILLIANCE; TUNABLE UNDULATOR;
D O I
10.7567/JJAPS.32S2.861
中图分类号
O59 [应用物理学];
学科分类号
摘要
Future prospects in XAFS researches to be developed by high brilliance photon sources are discussed. Above a dilute limit, sensitivity and time resolution am enhanced with the increase in brilliance, detector effeciency and focusing capability. It is shown that a multipole wiggler and multi-element solid state detector improve both sensitivity and time resolution by an order of magnitude. Applications to structural studies of dilute systems. in particular, surface and interfaces are presented. A ''tunable'' X-ray undulator inserted in an ultra-low (<10 nrad) emittance storage ring, which covers a hard X-ray (4-30 keV) region using the fundamental and third higher harmonic radiations, further improves the present limitations on sensitivity and resolutions in time, space and energy. Feasibility of a variable gap/bandpath undulator combined with new quick scanning techniques for applications in time-resolved studies is discussed. By optimizing an undulator band width for a scan, without varying undulator gap, XAFS is obtained by simple scanning of monochromator (Q-scan I). A new quick scanning technique for time-resolved studies on dilute systems based on an energy dispersive geometry (Q-scan II) is proposed. Design considerations of a ''tunable'' X-ray undulator XAFS beamline at SPring-8 are presented, in which either a high flux or a microfocus high energy resolution beam is obtained by a fixed-exit double-axis (2+2) crystal monochromator followed by crossed eliptical mirrors. A concept of ''ring'' detector for microfucusing in a fluorescence detection mode is also proposed.
引用
收藏
页码:861 / 865
页数:5
相关论文
共 18 条
[1]   X-RAY EVANESCENT-WAVE ABSORPTION AND EMISSION [J].
BECKER, RS ;
GOLOVCHENKO, JA ;
PATEL, JR .
PHYSICAL REVIEW LETTERS, 1983, 50 (03) :153-156
[2]   PERFORMANCE OF WATER JET COOLED SILICON MONOCHROMATORS ON A MULTIPOLE WIGGLER BEAM LINE AT NSLS [J].
BERMAN, LE ;
HART, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 300 (02) :415-421
[3]  
ELLEAUME P, 1991, X RAY ABSORPTION FIN, P646
[4]  
FONTAIN A, 1993, JPN J APPL PHYS, V32
[5]  
HEALD SM, 1984, PHYS LETT A, V103, P155, DOI 10.1016/0375-9601(84)90224-X
[6]   BEAMLINE X-11A AT THE NSLS - A UNIQUE FACILITY FOR X-RAY ABSORPTION-SPECTROSCOPY [J].
HEALD, SM ;
SAYERS, DE .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1932-1935
[7]  
MAROT G, IN PRESS REV SIC INS
[8]   A FAST X-RAY ABSORPTION SPECTROMETER FOR USE WITH SYNCHROTRON RADIATION [J].
MATSUSHITA, T ;
PHIZACKERLEY, RP .
JAPANESE JOURNAL OF APPLIED PHYSICS, 1981, 20 (11) :2223-2228
[9]   PERFORMANCE OF A DIRECTLY WATER-COOLED SILICON CRYSTAL FOR USE IN HIGH-POWER SYNCHROTRON RADIATION APPLICATIONS [J].
OVERSLUIZEN, T ;
MATSUSHITA, T ;
ISHIKAWA, T ;
STEFAN, PM ;
SHARMA, S ;
MIKUNI, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1493-1500
[10]   SI/GE/SI MONOLAYER HETEROSTRUCTURE ON SI(100) STUDIED BY SURFACE-SENSITIVE EXAFS [J].
OYANAGI, H ;
SAKAMOTO, T ;
SAKAMOTO, K ;
MATSUSHITA, T ;
YAO, T ;
ISHIGURO, T .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1988, 57 (06) :2086-2092