ENHANCEMENT OF THROMBOLYSIS BY EXTERNAL ULTRASOUND

被引:104
作者
LUO, H
STEFFEN, W
CERCEK, B
ARUNASALAM, S
MAURER, G
SIEGEL, RJ
机构
[1] CEDARS SINAI MED CTR,DIV CARDIOL,ROOM 5314,8700 BEVERLY BLVD,LOS ANGELES,CA 90048
[2] UNIV CALIF LOS ANGELES,SCH MED,LOS ANGELES,CA 90024
关键词
D O I
10.1016/0002-8703(93)90741-Q
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of our study was to assess the efficacy of external ultrasound to enhance in vitro thrombolysis with urokinase or streptokinase. One-hour-, 1-day-, 4-day-, and 6-day-old human blood thrombi (n = 366) were incubated in normal saline solution with three different concentrations of streptokinase (50, 250, and 2000 mu/ml) or urokinase (200, 2000, and 5000 mu/ml). Thrombi were exposed to pulsed ultrasound of 1 MHz at 1.0, 1.5 and 2.2 W/cm2 at different exposure times. The combination of ultrasound (2.2 W/cm2, 30 min) and urokinase or streptokinase enhanced lysis rate by an average of 25% compared with lysis with thrombolytic agents alone (p < 0.05). The enhancement was greater at higher ultrasound power outputs (2.2 W/cm2 > 1.5 W/cm2 > 1.0 W/cm2). At higher-power outputs there was no increase of temperature in the solution containing the thrombus. The extent of lysis was higher with longer ultrasound exposure time and with fresh thrombi. These data suggest that use of external ultrasound has the potential to increase both efficacy and rate of thrombolysis.
引用
收藏
页码:1564 / 1569
页数:6
相关论文
共 20 条
[1]   DISSOLUTION OF PERIPHERAL ARTERIAL THROMBI BY ULTRASOUND [J].
ARIANI, M ;
FISHBEIN, MC ;
CHAE, JS ;
SADEGHI, H ;
MICHAEL, TAD ;
DUBIN, SB ;
SIEGEL, RJ .
CIRCULATION, 1991, 84 (04) :1680-1688
[2]  
CERCEK B, 1986, CLIN RES, V34, pA5
[3]   THROMBOLYTIC THERAPY [J].
COLLEN, D ;
STUMP, DC ;
GOLD, HK .
ANNUAL REVIEW OF MEDICINE, 1988, 39 :405-423
[4]   INTRA-CORONARY THROMBOLYSIS IN EVOLVING MYOCARDIAL-INFARCTION [J].
GANZ, W ;
BUCHBINDER, N ;
MARCUS, H ;
MONDKAR, A ;
MADDAHI, J ;
CHARUZI, Y ;
OCONNOR, L ;
SHELL, W ;
FISHBEIN, MC ;
KASS, R ;
MIYAMOTO, A ;
SWAN, HJC .
AMERICAN HEART JOURNAL, 1981, 101 (01) :4-13
[5]   A SEARCH FOR ULTRASONIC CAVITATION WITHIN THE CANINE CARDIOVASCULAR-SYSTEM [J].
GROSS, DR ;
MILLER, DL ;
WILLIAMS, AR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (01) :85-97
[6]  
HAMANO K, 1991, European Heart Journal, V12, P135
[7]   ULTRASONIC CLOT DISRUPTION - AN INVITRO STUDY [J].
HONG, AS ;
CHAE, JS ;
DUBIN, SB ;
LEE, S ;
FISHBEIN, MC ;
SIEGEL, RJ .
AMERICAN HEART JOURNAL, 1990, 120 (02) :418-422
[8]  
LAWRENCE PF, 1992, SURG CLIN N AM, V72, P899
[9]   THROMBUS AGE AND TISSUE PLASMINOGEN-ACTIVATOR MEDIATED THROMBOLYSIS IN RATS [J].
LOREN, M ;
FRADE, LJG ;
TORRADO, MC ;
NAVARRO, JL .
THROMBOSIS RESEARCH, 1989, 56 (01) :67-76
[10]   THROMBOLYTIC THERAPY - CURRENT STATUS .2. [J].
MARDER, VJ ;
SHERRY, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 318 (24) :1585-1595