STETHOSCOPE CONTAMINATION IN THE NEONATAL INTENSIVE-CARE UNIT

被引:36
作者
WRIGHT, IMR
ORR, H
PORTER, C
机构
[1] Department of Paediatrics and Child Health, Leeds General Infirmary, Leeds, LS2 9NS, Belmont Grove
[2] Peter Congdon Neonatal Unit, Clarendon Wing, Leeds General Infirmary, Leeds, LS2 9NS, Belmont Grove
关键词
NEONATAL INTENSIVE CARE; STETHOSCOPE; NOSOCOMIAL INFECTION; CLEANING PRACTICES;
D O I
10.1016/0195-6701(95)90294-5
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The level of contamination of stethoscopes used in a neonatal intensive care unit was studied, along with the practices used for cleaning these items. A policy of alcohol cleaning was introduced and the effect of this change on the level of bacterial growth was observed after a six-week period. It was found that 71% of stethoscopes had a significant bacterial growth and that this was reduced to 30% after the cleaning procedure change (P<0.05). Stethoscopes and other equipment are a potential source of nosocomial infection on the neonatal intensive care unit.
引用
收藏
页码:65 / 68
页数:4
相关论文
共 4 条
[1]   HAND DISINFECTION - A COMPARISON OF VARIOUS AGENTS IN LABORATORY AND WARD STUDIES [J].
AYLIFFE, GAJ ;
BABB, JR ;
DAVIES, JG ;
LILLY, HA .
JOURNAL OF HOSPITAL INFECTION, 1988, 11 (03) :226-243
[2]   STETHOSCOPES AS POSSIBLE VECTORS OF INFECTION BY STAPHYLOCOCCI [J].
BREATHNACH, AS ;
JENKINS, DR ;
PEDLER, SJ .
BRITISH MEDICAL JOURNAL, 1992, 305 (6868) :1573-1574
[3]   RECEIVER OPERATING CHARACTERISTIC CURVES FOR COMPARISON OF SERIAL NEUTROPHIL BAND FORMS AND C-REACTIVE PROTEIN IN NEONATES AT RISK OF INFECTION [J].
RUSSELL, GAB ;
SMYTH, A ;
COOKE, RWI .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1992, 67 (07) :808-812
[4]   AN IN-USE COMPARISON OF CHLORHEXIDINE GLUCONATE 4-PERCENT W/V, GLYCOL-POLY-SILOXANE PLUS METHYLCELLULOSE AND A LIQUID SOAP IN A SPECIAL CARE BABY UNIT [J].
WEBSTER, J ;
FAOAGALI, JL .
JOURNAL OF HOSPITAL INFECTION, 1989, 14 (02) :141-151