Standard method for microCT-based additive manufacturing quality control 4: Metal powder analysis

被引:36
作者
du Plessis, Anton [1 ]
Sperling, Philip [2 ]
Beerlink, Andre [2 ]
du Preez, Willie B. [3 ]
le Roux, Stephan G. [1 ]
机构
[1] Stellenbosch Univ, CT Scanner Facil, Stellenbosch, South Africa
[2] YXLON Int GmbH, Hamburg, Germany
[3] Cent Univ Technol, Dept Mech Engn Dept, Bloemfontein, Free State, South Africa
来源
METHODSX | 2018年 / 5卷
关键词
Additive manufacturing; MicroCT; X-ray; Tomography; Non-destructive testing; Powder; Particle; Characterization;
D O I
10.1016/j.mex.2018.10.021
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
X-ray micro computed tomography (microCT) can be applied to analyse powder feedstock used in additive manufacturing. In this paper, we demonstrate a dedicated workflow for this analysis method, specifically for Ti6Al4V powder typically used in commercial powder bed fusion (PBF) additive manufacturing (AM) systems. The methodology presented includes sample size requirements, scan conditions and settings, reconstruction and image analysis procedures. We envisage this method will support standardization in powder analysis in the additive manufacturing community. This is aimed at ultimately improving the quality of additively manufactured parts, through the identification of impurities and defects in powders. MicroCT analysis of metal powders for additive manufacturing Method describes a standard workflow simplifying usage of the technique Sample requirements and image analysis workflow is described (C) 2018 The Author(s). Published by Elsevier B.V.
引用
收藏
页码:1336 / 1345
页数:10
相关论文
共 18 条
[1]   Additive manufacturing powder feedstock characterization using X-ray tomography [J].
Bernier F. ;
Tahara R. ;
Gendron M. .
Bernier, Fabrice (Fabrice.Bernier@cnrc-nrc.gc.ca), 2018, Elsevier Ltd (73) :158-162
[2]   Analyzing the effects of powder and post-processing on porosity and properties of electron beam melted Ti-6Al-4V [J].
Cunningham, Ross ;
Nicolas, Andrea ;
Madsen, John ;
Fodran, Eric ;
Anagnostou, Elias ;
Sangid, Michael D. ;
Rollett, Anthony D. .
MATERIALS RESEARCH LETTERS, 2017, 5 (07) :516-525
[3]  
du Plessis A., 2018, ADDIT MANUF
[4]   Standard method for microCT-based additive manufacturing quality control 3: Surface roughness [J].
du Plessis, Anton ;
Sperling, Philip ;
Beerlink, Andre ;
Kruger, Oelof ;
Tshabalala, Lerato ;
Hoosain, Shaik ;
le Roux, Stephan G. .
METHODSX, 2018, 5 :1111-1116
[5]   X-Ray Microcomputed Tomography in Additive Manufacturing: A Review of the Current Technology and Applications [J].
du Plessis, Anton ;
Yadroitsev, Igor ;
Yadroitsava, Ina ;
Le Roux, Stephan G. .
3D PRINTING AND ADDITIVE MANUFACTURING, 2018, 5 (03) :227-247
[6]   Standard method for microCT-based additive manufacturing quality control 1: Porosity analysis [J].
du Plessis, Anton ;
Sperling, Philip ;
Beerlink, Andre ;
Tshabalala, Lerato ;
Hoosain, Shaik ;
Mathe, Ntombi ;
le Roux, Stephan G. .
METHODSX, 2018, 5 :1102-1110
[7]   Laboratory x-ray micro-computed tomography: a user guideline for biological samples [J].
du Plessis, Anton ;
Broeckhoven, Chris ;
Guelpa, Anina ;
le Roux, Stephan Gerhard .
GIGASCIENCE, 2017, 6 (06)
[8]   The CT Scanner Facility at Stellenbosch University: An open access X-ray computed tomography laboratory [J].
du Plessis, Anton ;
le Roux, Stephan Gerhard ;
Guelpa, Anina .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 384 :42-49
[9]  
DuPlessis A., 2018, METHODSX
[10]   Three-dimensional mathematical analysis of particle shape using X-ray tomography and spherical harmonics: Application to aggregates used in concrete [J].
Garboczi, EJ .
CEMENT AND CONCRETE RESEARCH, 2002, 32 (10) :1621-1638