EFFECTS OF INDIVIDUALLY CONSTRUCTED ORAL APPLIANCE ON THE POLYSOMNOGRAPHIC PARAMETERS IN PATIENTS WITH OBSTRUCTIVE SLEEP APNEA

被引:0
作者
Grozev, Lyubomir [1 ]
Terziyski, Kiril [2 ]
Draganova, Aneliya [2 ]
Hristov, Iliyan [1 ]
机构
[1] Med Univ Plovdiv, Fac Dent Med, Dept Prosthet Dent, 15A,Vassil Aprilov Blvd, Plovdiv, Bulgaria
[2] Med Univ Plovdiv, Dept Pathophysiol, Fac Med, Plovdiv, Bulgaria
来源
JOURNAL OF IMAB | 2018年 / 24卷 / 02期
关键词
oral appliance; obstructive sleep apnea; polysomnography;
D O I
10.5272/jimab.2018242.1978
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Obstructive sleep apnea (OSA) is a common sleep disorder, associated with disturbed noxturnal oxygenation profile and altered sleep structure, associated with significant health problems. Oral appliances (OA) are used as an alternative therapeutic option for patients with mild to moderate OSA. Although the application of OA does not always result in a complete resolution of the sleep-disordered breathing, greater patient adherence is demonstrated. We have decided to evaluate the effect of individually constructed OA on sleep disordered breathing and sleep structure in patients with OSA. Materials and methods: 20 patients (18 men) with OSA (age 46.3 +/- 8.1 years (mean +/- SD), body mass index 29.0 +/- 4.8 kg.m(-2)) were subjected to a full-night polysomnography (PSG), at baseline and one month after the introduction of an OA. Results: A significant decrease in AHI (33.4 +/- 31.1 vs 45.5 +/- 30.8, p<0.001), hypopnea index (10.3 +/- 9.1 vs 18.2 +/- 11.0, p=0.023), mean duration of apneas (20.9 +/- 6.9 vs 24.1 +/- 6.4 sec, p=0.005) and average desaturation (5.6 +/- 2.4 vs 8.5 +/- 3.0 %, p<0.001), after therapy and at baseline, respectively, was registered. Sleep structure was improved as indicated by an increase in REM (16.1 +/- 6.2vs 12.3 +/- 8.2 % of total sleep time, p=0.016) and a decrease in arousal index (31.0 +/- 14.2 vs 46.4 +/- 12.0, p<0.001). Conclusion: OA is a reasonable alternative for the treatment of patients with moderate and severe OSA, resulting in an improvement of the polysomnographic parameters and expressed by excellent patient compliance.
引用
收藏
页码:1978 / 1984
页数:7
相关论文
共 27 条
  • [1] Effects of an oral appliance with different mandibular protrusion positions at a constant vertical dimension on obstructive sleep apnea
    Aarab, Ghizlane
    Lobbezoo, Frank
    Hamburger, Hans L.
    Naeije, Machiel
    [J]. CLINICAL ORAL INVESTIGATIONS, 2010, 14 (03) : 339 - 345
  • [2] Rules for Scoring Respiratory Events in Sleep: Update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events
    Berry, Richard B.
    Budhiraja, Rohit
    Gottlieb, Daniel J.
    Gozal, David
    Iber, Conrad
    Kapur, Vishesh K.
    Marcus, Carole L.
    Mehra, Reena
    Parthasarathy, Sairam
    Quan, Stuart F.
    Redline, Susan
    Strohl, Kingman P.
    Ward, Sally L. Davidson
    Tangredi, Michelle M.
    [J]. JOURNAL OF CLINICAL SLEEP MEDICINE, 2012, 8 (05): : 597 - 619
  • [3] Oral appliance treatment of obstructive sleep apnea: an update
    Chan, Andrew S. L.
    Cistulli, Peter A.
    [J]. CURRENT OPINION IN PULMONARY MEDICINE, 2009, 15 (06) : 591 - 596
  • [4] A crossover study comparing the efficacy of continuous positive airway pressure with anterior mandibular positioning devices on patients with obstructive sleep apnea
    Clark, GT
    Blumenfeld, I
    Yoffe, N
    Peled, E
    Lavie, P
    [J]. CHEST, 1996, 109 (06) : 1477 - 1483
  • [5] Obstructive sleep apnea - Oral appliance therapy and severity of condition
    Cohen, R
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 85 (04): : 388 - 392
  • [6] Randomized crossover trial of two treatments for sleep apnea/hypopnea syndrome - Continuous positive airway pressure and mandibular repositioning splint
    Engleman, HM
    McDonald, JP
    Graham, D
    Lello, GE
    Kingshott, RN
    Coleman, EL
    Mackay, TW
    Douglas, NJ
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (06) : 855 - 859
  • [7] A randomized crossover study of an oral appliance vs nasal-continuous positive airway pressure in the treatment of mild-moderate obstructive sleep apnea
    Ferguson, KA
    Ono, T
    Lowe, AA
    Keenan, SP
    Fleetham, JA
    [J]. CHEST, 1996, 109 (05) : 1269 - 1275
  • [8] Efficacy and co-morbidity of oral appliances in the treatment of obstructive sleep apnea-hypopnea: A systematic review
    Hoekema, A
    Stegenga, B
    de Bont, LGM
    [J]. CRITICAL REVIEWS IN ORAL BIOLOGY & MEDICINE, 2004, 15 (03) : 137 - 155
  • [9] Compliance with continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea among privately paying patients- a cross sectional study
    Hussain, Syed Fayyaz
    Irfan, Muhammad
    Waheed, Zeeshan
    Alam, Naveen
    Mansoor, Saba
    Islam, Muhammad
    [J]. BMC PULMONARY MEDICINE, 2014, 14
  • [10] Iber C., 2007, AASM MANUAL SCORING, V1st ed.