High-Sensitivity Bunch Charge Monitor

被引:0
|
作者
Lebedev, N. I. [1 ]
Fateev, A. A. [1 ]
机构
[1] JINR, Dubna, Russia
关键词
D O I
10.1134/S1547477108070169
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The conceptual design for a high-sensitivity bunch charge monitor is presented. The device operates with short, spaced bunches. For optimal performance, the bunch duration should be less than 10 ns and bunch spacing should be more than 100 ns. Sensitivity of the monitor is close to 10 V per nanocoulomb. The equivalent scheme and the output signal shape are also presented. Such a monitor seems to be promising for the bunch charge measurements of beams like those in TESLA or ILC projects.
引用
收藏
页码:609 / 611
页数:3
相关论文
共 50 条
  • [1] High-sensitivity bunch charge monitor
    N. I. Lebedev
    A. A. Fateev
    Physics of Particles and Nuclei Letters, 2008, 5 (7) : 609 - 611
  • [2] A HIGH-SENSITIVITY CONTINUOUS PLUTONIUM AIR MONITOR
    TANAKA, E
    IWADATE, S
    MIWA, H
    HEALTH PHYSICS, 1968, 14 (05): : 473 - +
  • [3] HIGH-SENSITIVITY ONLINE MONITOR FOR RADIOACTIVE EFFLUENT
    SASAKI, T
    ISHIZUKA, A
    ABE, E
    INOUE, Y
    FUJII, M
    KITAGUCHI, H
    DOI, A
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 43 : 62 - 63
  • [4] HIGH-SENSITIVITY ONLINE MONITOR FOR RADIOACTIVE EFFLUENT
    SASAKI, T
    ISHIZUKA, A
    ABE, E
    INOUE, Y
    FUJII, M
    KITAGUCHI, H
    DOI, A
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1983, 20 (04) : 317 - 321
  • [5] A high-sensitivity particle monitor using an integration sphere
    Yamaguchi, T
    Watanabe, K
    Nakayama, M
    Gao, YZ
    Nagasawa, T
    Ozawa, T
    IMTC/99: PROCEEDINGS OF THE 16TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS. 1-3, 1999, : 418 - 423
  • [6] A high-sensitivity particle monitor using an integration sphere
    Watanabe, K
    Yamaguchi, T
    Nakayama, M
    Gao, YZ
    Nagasawa, T
    Ozawa, T
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (03) : 679 - 684
  • [7] A HIGH-SENSITIVITY PHASE STABILIZING SYSTEM AND BEAM CURRENT MONITOR
    FACCO, A
    RUDOLPH, K
    BASSATO, G
    BATTISTELLA, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3): : 253 - 257
  • [8] Fast charge preamplifier for high-sensitivity fission chamber
    Yuan, Guoliang
    Yang, Qingwei
    Wen, Zuowei
    Zhao, Li
    Wei, Lingfeng
    Li, Yong
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2020, 968
  • [9] HIGH-SENSITIVITY MINIATURE-SIZED MICROWAVE-POWER MONITOR
    YOKOO, K
    AGARWAL, R
    HARTNAGEL, H
    ELECTRONICS LETTERS, 1976, 12 (03) : 67 - 68
  • [10] HIGH-SENSITIVITY GAMMA-RADIATION MONITOR FOR TEACHING AND ENVIRONMENTAL APPLICATIONS
    LYONS, RG
    CROSSLEY, PC
    FORTUNE, D
    JOURNAL OF CHEMICAL EDUCATION, 1994, 71 (06) : 524 - 527