SILICONE BREAST IMPLANT RUPTURES IN AN ANIMAL-MODEL - COMPARISON OF MAMMOGRAPHY, MR-IMAGING, US, AND CT

被引:41
作者
GORCZYCA, DP
DEBRUHL, ND
AHN, CY
HOYT, A
SAYRE, JW
NUDELL, PP
MCCOMBS, M
SHAW, WW
BASSETT, LW
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DIV PLAST & RECONSTRUCT SURG,LOS ANGELES,CA 90024
[2] UNIV CALIF LOS ANGELES,SCH MED,JONSSON COMPREHENS CANC CTR,LOS ANGELES,CA 90024
关键词
BREAST; CT; MR; PROSTHESES; BREAST US; MAGNETIC RESONANCE; COMPARATIVE STUDIES; SILICONE;
D O I
10.1148/radiology.190.1.8259410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the most accurate imaging modality for detection of silicone implant ruptures. MATERIALS AND METHODS: Forty single-lumen silicone implants were surgically placed in 20 rabbits. Each rabbit received one intact and one ruptured implant and was examined with mammography, magnetic resonance (MR) imaging, ultrasound (US), and computed tomography (CT). Five radiologists reviewed all images in a random fashion and graded each for rupture. The radiologist who performed US also graded her impression during examination with US. Receiver operating characteristic (ROC) analysis was performed. RESULTS: MR imaging and CT were the most accurate modalities in detection of implant ruptures, with areas under the ROC curves (A(z)) of.95 and .91. Mammography and US were statistically significantly inferior, with A(z) of.77 for each (P < .05). CONCLUSION: MR imaging and CT are statistically more accurate than US and mammography for detection of intracapsular silicone implant ruptures when only the images are reviewed.
引用
收藏
页码:227 / 232
页数:6
相关论文
共 15 条
  • [1] SILICONE BREAST IMPLANTS - US EVALUATION
    DEBRUHL, ND
    GORCZYCA, DP
    AHN, CY
    SHAW, WW
    BASSETT, LW
    [J]. RADIOLOGY, 1993, 189 (01) : 95 - 98
  • [2] SCREENING MAMMOGRAPHY IN 350 WOMEN WITH BREAST IMPLANTS - PREVALENCE AND FINDINGS OF IMPLANT COMPLICATIONS
    DESTOUET, JM
    MONSEES, BS
    OSER, RF
    NEMECEK, JR
    YOUNG, VL
    PILGRAM, TK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (05) : 973 - 978
  • [3] IMPROVED IMAGING OF THE AUGMENTED BREAST
    EKLUND, GW
    BUSBY, RC
    MILLER, SH
    JOB, JS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (03) : 469 - 473
  • [4] AUGMENTATION MAMMAPALSTY - NORMAL AND ABNORMAL FINDINGS WITH MAMMOGRAPHY AND ULTRASOUND
    GANOTT, MA
    HARRIS, KM
    ILKHANIPOUR, ZS
    COSTAGRECO, MA
    [J]. RADIOGRAPHICS, 1992, 12 (02) : 281 - 295
  • [5] SILICONE BREAST IMPLANTS INVIVO - MR IMAGING
    GORCZYCA, DP
    SINHA, S
    AHN, CY
    DEBRUHL, ND
    HAYES, MK
    GAUSCHE, VR
    SHAW, WW
    BASSETT, LW
    [J]. RADIOLOGY, 1992, 185 (02) : 407 - 410
  • [6] SILICONE IMPLANT RUPTURE - DETECTION WITH US
    HARRIS, KM
    GANOTT, MA
    SHESTAK, KC
    LOSKEN, HW
    TOBON, H
    [J]. RADIOLOGY, 1993, 187 (03) : 761 - 768
  • [7] THE BASIS OF THE FDAS DECISION ON BREAST IMPLANTS
    KESSLER, DA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (25) : 1713 - 1715
  • [8] DEFINITIVE DIAGNOSIS OF BREAST IMPLANT RUPTURE BY ULTRASONOGRAPHY
    LEVINE, RA
    COLLINS, TL
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1991, 87 (06) : 1126 - 1128
  • [10] METZ CE, 1984, INFORMATION PROCESSI, P432