LOCALIZATION OF THE PROSTATIC APEX FOR RADIATION-THERAPY USING IMPLANTED MARKERS

被引:71
作者
SANDLER, HM
BREE, RL
MCLAUGHLIN, PW
GROSSMAN, HB
LICHTER, AS
机构
[1] UNIV MICHIGAN,MED CTR,DEPT RADIOL,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,MED CTR,UROL SECT,ANN ARBOR,MI 48109
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1993年 / 27卷 / 04期
关键词
PROSTATIC NEOPLASMS; RADIOTHERAPY; TREATMENT PLANNING;
D O I
10.1016/0360-3016(93)90468-B
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This report concentrates on the localization of the prostatic apex using implantable markers, and a comparison to localization defined by computed tomography (CT) and retrograde urethrography. Methods and Materials: Fifteen patients were entered into a prospective trial and scheduled to undergo (a) pelvic CT, (b) retrograde urethrogram, and (c) transrectal ultrasound with placement of radiodense markers. Three markers were implanted: one was placed at the trapezoid area (prostatic apex), and the others placed lateral to the base of each seminal vesicle. The retrograde urethrogram was performed using standard technique. The superior-inferior distance between the apex identified by the marker placed at the prostatic apex and the other studies was measured. Results: CT and urethrogram overestimated the inferior extent of the prostatic apex when compared to the location as defined by the implanted marker. With CT, the average distance from the marker to the CT-defined apex was 0.6 cm (95% C.I.-0.4-0.8 cm). With urethrogram, the average distance from the marker to the urethrogram-defined apex was 1.3 cm (95% C.I.-0.7-1.9 cm). When CT and urethrogram were compared, CT was more accurate in identifying the prostatic apex. Conclusion: Under ultrasound guidance, radiodense markers have been implanted into the prostate. This has revealed that the apex is localized superior to the apical margin as defined by retrograde urethrogram and CT, and that CT may be more accurate than retrograde urethrogram. In addition, the placement of multiple markers yields spatial information on prostatic position that can be extracted from megavoltage portal images.
引用
收藏
页码:915 / 919
页数:5
相关论文
共 21 条
[1]  
Bentel GCNC, 1989, TREATMENT PLANNING D
[2]   CANCER STATISTICS, 1992 [J].
BORING, CC ;
SQUIRES, TS ;
TONG, T .
CA-A CANCER JOURNAL FOR CLINICIANS, 1992, 42 (01) :19-38
[3]   REACTION OF FIBROBLASTS TO VARIOUS DENTAL CASTING ALLOYS [J].
CRAIG, RG ;
HANKS, CT .
JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1988, 17 (07) :341-347
[4]  
HAFERMANN MD, 1983, INT J RAD ONCOL B S1, V9, P150
[5]  
HANKS GE, 1988, CANCER, V61, P2153, DOI 10.1002/1097-0142(19880601)61:11<2153::AID-CNCR2820611104>3.0.CO
[6]  
2-0
[7]  
HANKS GE, 1989, RADIAT ONCOL, P487
[8]  
KABALIN JN, 1989, J UROLOGY, V142, P873
[9]   TRANS-RECTAL ULTRASOUND IN THE DIAGNOSIS AND STAGING OF PROSTATIC-CARCINOMA [J].
LEE, F ;
TORPPEDERSEN, ST ;
SIDERS, DB ;
LITTRUP, PJ ;
MCLEARY, RD .
RADIOLOGY, 1989, 170 (03) :609-615
[10]  
LEE F, 1989, UROL CLIN N AM, V16, P663