Comparison of Lung Ultrasound-based Weaning Indices with Rapid Shallow Breathing Index: Are They Helpful?

被引:27
作者
Banerjee, Abhinav [1 ]
Mehrotra, Gesu [1 ]
机构
[1] Tata Main Hosp, Dept Anesthesiol & Crit Care, Jamshedpur, Jharkhand, India
关键词
Extubation predictor; lung ultrasound; rapid shallow breathing index; weaning process;
D O I
10.4103/ijccm.IJCCM_331_17
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background and Aims: The diaphragm is considered the main respiratory muscle and difficulty in weaning can occur because of impaired diaphragmatic function. Hence, monitoring diaphragmatic function is important. The aim of this study is to assess the ability of various lung ultrasound (US) indices and the rapid shallow breathing index (RSBI) to predict the outcome of the weaning process and compare them with RSBI. Materials and Methods: This was a prospective study conducted on patients admitted to critical care unit at a tertiary care hospital in north India from February 2017 to June 2017. Patients were put to spontaneous breathing trial (SBT) when they met the weaning criteria. Initial US was done immediately after putting the patient on SBT to check anatomy of the diaphragm and rule out patients according to exclusion criteria. This was followed by complete lung US (LUS) after 20 min of SBT. Results: The RSBI performed better than all other parameters, with an area under the curve (AUC) of 0.996. The sensitivity and specificity is 100%. Only comparable to RSBI is the speed of diaphragmic contraction (DC) which has AUC of 0.93. All other parameters had an AUC <0.8. Moreover, the DC and LUS score are strongly positively correlated with RSBI, whereas diaphragmic excursion and diaphragmic thickness fraction (DTF %) are weakly correlated. Conclusion: In Intensive Care Unit, RSBI is the best clinical tool for weaning, and DC is found to be the best parameter for weaning among the US-based weaning parameters. It can even be a substitute for RSBI, in today's world of real-time monitoring methods.
引用
收藏
页码:435 / 440
页数:6
相关论文
共 20 条
  • [1] Baess AI, 2016, EGYPT J BRONCHOL, V10, DOI DOI 10.4103/1687-8426.184370
  • [2] Diaphragmatic Motion Studied by M-Mode Ultrasonography Methods, Reproducibility, and Normal Values
    Boussuges, Alain
    Gole, Yoann
    Blanc, Philippe
    [J]. CHEST, 2009, 135 (02) : 391 - 400
  • [3] Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilation
    DiNino, Ernest
    Gartman, Eric J.
    Sethi, Jigme M.
    McCool, F. Dennis
    [J]. THORAX, 2014, 69 (05) : 423 - 427
  • [4] The prognostic significance of passing a daily screen of weaning parameters
    Ely, EW
    Baker, AM
    Evans, GW
    Haponik, EF
    [J]. INTENSIVE CARE MEDICINE, 1999, 25 (06) : 581 - 587
  • [5] Epstein Scott K, 2002, Respir Care, V47, P483
  • [6] Characteristics and outcomes in adult patients receiving mechanical ventilation -: A 28-day international study
    Esteban, A
    Anzueto, A
    Frutos, F
    Alía, I
    Brochard, L
    Stewart, TE
    Benito, S
    Epstein, SK
    Apezteguía, C
    Nightingale, P
    Arroliga, AC
    Tobin, MJ
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 287 (03): : 345 - 355
  • [7] Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation
    Ferrari G.
    De Filippi G.
    Elia F.
    Panero F.
    Volpicelli G.
    Aprà F.
    [J]. Critical Ultrasound Journal, 2014, 6 (1) : 1 - 6
  • [8] PREFERENTIAL FATIGUE OF THE RIB CAGE MUSCLES DURING INSPIRATORY RESISTIVE LOADED VENTILATION
    HERSHENSON, MB
    KIKUCHI, Y
    TZELEPIS, GE
    MCCOOL, FD
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (02) : 750 - 754
  • [9] RELATIVE STRENGTHS OF THE CHEST WALL MUSCLES
    HERSHENSON, MB
    KIKUCHI, Y
    LORING, SH
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1988, 65 (02) : 852 - 862
  • [10] RAPID SHALLOW BREATHING (FREQUENCY-TIDAL VOLUME RATIO) DID NOT PREDICT EXTUBATION OUTCOME
    LEE, KH
    HUI, KP
    CHAN, TB
    TAN, WC
    LIM, TK
    [J]. CHEST, 1994, 105 (02) : 540 - 543