A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study

被引:12
作者
Ashraf, Fauzia [1 ]
Shankarappa, Pushpa [1 ]
Misra, Abhinav [1 ]
Sawhney, Asheesh [1 ]
Sridevi, Nandamuri [1 ]
Singh, Anu [1 ]
机构
[1] Hosp & Res Ctr, Rama Dent Coll, Dept Conservat Dent & Endodont, Kanpur 208024, Uttar Pradesh, India
关键词
D O I
10.1155/2016/8379865
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p < 0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects.
引用
收藏
页数:7
相关论文
共 16 条
[1]   Deformation of HyFlex CM instruments and their shape recovery following heat sterilization [J].
Alazemi, M. Alfoqom ;
Bryant, S. T. ;
Dummer, P. M. H. .
INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (06) :593-601
[2]   Effect of ProTaper Universal, Endoflare, Revo-S, HyFlex Coronal Flaring Instruments, and Gates Glidden Drills on Crack Formation [J].
Arslan, Hakan ;
Karatas, Ertugrul ;
Capar, Ismail Davut ;
Ozsu, Damla ;
Doganay, Ezgi .
JOURNAL OF ENDODONTICS, 2014, 40 (10) :1681-1683
[3]   Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper [J].
Buerklein, S. ;
Hinschitza, K. ;
Dammaschke, T. ;
Schaefer, E. .
INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (05) :449-461
[4]   Effects of ProTaper Universal, ProTaper Next, and HyFlex Instruments on Crack Formation in Dentin [J].
Capar, Ismail Davut ;
Arslan, Hakan ;
Akcay, Merve ;
Uysal, Banu .
JOURNAL OF ENDODONTICS, 2014, 40 (09) :1482-1484
[5]  
Gianluca G., 2005, ENDOD TOPICS, V10, P179, DOI [10.1111/j.1601-1546.2005.00119.x, DOI 10.1111/j.1601-1546.2005.00119.x]
[6]   Fracture strength of tooth roots following canal preparation by hand and rotary instrumentation [J].
Lam, PPS ;
Palamara, JEA ;
Messer, HH .
JOURNAL OF ENDODONTICS, 2005, 31 (07) :529-532
[7]   Incidence of Apical Root Cracks and Apical Dentinal Detachments after Canal Preparation with Hand and Rotary Files at Different Instrumentation Lengths [J].
Liu, Rui ;
Kaiwar, Anjali ;
Shemesh, Hagay ;
Wesselink, Paul R. ;
Hou, Benxiang ;
Wu, Min-Kai .
JOURNAL OF ENDODONTICS, 2013, 39 (01) :129-132
[8]   Physical and mechanical properties of a thermomechanically treated NiTi wire used in the manufacture of rotary endodontic instruments [J].
Pereira, E. S. J. ;
Peixoto, I. F. C. ;
Viana, A. C. D. ;
Oliveira, I. I. ;
Gonzalez, B. M. ;
Buono, V. T. L. ;
Bahia, M. G. A. .
INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (05) :469-474
[9]   Determining cutting efficiency of nickel-titanium coronal flaring instruments used in lateral action [J].
Peters, O. A. ;
Morgental, R. D. ;
Schulze, K. A. ;
Paque, F. ;
Kopper, P. M. P. ;
Vier-Pelisser, F. V. .
INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (06) :505-513
[10]  
Priya N. T., 2014, J CLIN DIAGNOSTIC RE, V8