A LIGHT-EMITTING DIODE LIGHT STANDARD FOR PHOTO-MICROSCOPY AND VIDEOMICROSCOPY

被引:10
作者
BEACH, JM
DULING, BR
机构
[1] UNIV VIRGINIA, HLTH SCI CTR, DEPT MOLEC PHYSIOL & BIOL PHYS, CHARLOTTESVILLE, VA 22908 USA
[2] UNIV VIRGINIA, HLTH SCI CTR, DEPT BIOMED ENGN, CHARLOTTESVILLE, VA 22908 USA
[3] UNIV VIRGINIA, HLTH SCI CTR, DEPT PHYSIOL, CHARLOTTESVILLE, VA 22908 USA
关键词
CALIBRATION; FLUORESCENT STANDARDS; LIGHT SOURCE; LIGHT-EMITTING DIODE (LED); OPTICAL FEEDBACK; PHOTOMICROSCOPY; VIDEOMICROSCOPY;
D O I
10.1111/j.1365-2818.1993.tb03391.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
A light calibration system consisting of a compact light-emitting diode (LED) source with feedback control of intensity is described. The source is positioned in the focal plane of the microscope objective and produces flat-field illumination of up to 31 mu W. The source can be easily used to determine the performance of microscope optics and camera response. It can also be used as a standard light source for calibration of experimental systems. Selectable light intensities are produced by controlling the LED input power via a feedback circuit consisting of a photodiode that detects output light intensity. Spectral coverage extends between 550 and 670 nm using green, yellow and red LEDs mounted side by side, which are selected individually. The LED chips are encapsulated in plastic diffusers which homogenize the light, and a flat field of illumination is obtained through a thin l-mm-diameter aperture positioned directly over each chip. Provision is made for insertion of Ronchi rulings over the aperture to enable measurements of contrast modulation in a uniform field. The light may be pulse-modulated to assess camera response times and the device can be synchronized with video frames. Narrow bandpass interference filters can be placed between the objective lens and the LED source to produce monochromatic light without affecting the spacing of controlled light intensities since emission spectra do not shift appreciably over the range of LED powers chosen in this design. Results of tests using controlled light intensity and uniform illumination are presented.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 12 条
  • [1] DIGITAL IMAGING FLUORESCENCE MICROSCOPY - SPATIAL HETEROGENEITY OF PHOTOBLEACHING RATE CONSTANTS IN INDIVIDUAL CELLS
    BENSON, DM
    BRYAN, J
    PLANT, AL
    GOTTO, AM
    SMITH, LC
    [J]. JOURNAL OF CELL BIOLOGY, 1985, 100 (04) : 1309 - 1323
  • [2] BRIGHT GR, 1989, METHOD CELL BIOL, V30, P157
  • [3] BRIGHT GR, 1986, APPLICATIONS FLUORES, P257
  • [4] Hansen E. R., 1986, VIDEO MICROSCOPY, P467
  • [5] TOTAL QUANTUM FLUX OF ISOTROPIC SOURCES
    HASTINGS, JW
    WEBER, G
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1963, 53 (12) : 1410 - &
  • [6] HEIPLE J, 1982, INTRACELLULAR PH ITS, P22
  • [7] INOUE S, 1986, VIDEO MICROSCOPY, P191
  • [8] INOUE S, 1986, VIDEO MICROSCOPY, pCH5
  • [9] SISKEN JE, 1989, METHOD CELL BIOL, V30, P113
  • [10] SPRING KR, 1989, METHOD CELL BIOL, V29, P270