Endoscopic ultrasound-guided fiducial marker placement for image-guided radiation therapy without fluoroscopy: safety and technical feasibility

被引:33
作者
Dhadham, Gautamy Chitiki [1 ]
Hoffe, Sarah [2 ]
Harris, Cynthia L. [1 ]
Klapman, Jason B. [1 ]
机构
[1] Univ S Florida, Coll Med, H Lee Moffitt Canc Ctr & Res Inst, Gastrointestinal Tumor Program,Div Endoscop Oncol, Tampa, FL 33612 USA
[2] Univ S Florida, Coll Med, H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL 33612 USA
关键词
D O I
10.1055/s-0042-100720
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims: Endoscopic ultrasound (EUS)-guided fiducial marker placement for image-guided radiation treatment (IGRT) is becoming more widespread. Most case series report the procedure performed using fluoroscopy for spatial geometry although the benefits of this are unclear. The aim of our study is to report the technical feasibility, safety, and migration rate of fiducial marker placement in a large cohort of patients with gastrointestinal malignancies who underwent EUS-guided fiducial marker placement for IGRT without fluoroscopy. Patients and methods: A retrospective chart review was performed on all patients referred for EUS-guided fiducial marker placement from 08/1/07 to 7/31/14 at Moffitt Cancer Center. Results: During the study period, 514 patients underwent placement of 1093 gold fiducial markers under EUS-guidance. Two hundred and forty patients with esophageal/gastro-esophageal junction cancer had 405 fiducials placed. In 188 patients with pancreatic ancer, 510 fiducials were placed. In 54 patients with rectal cancer, 103 fiducials were placed and 32 patients had 75 fiducials placed into other gastrointestinal tract lesions. Minor bleeding, which resolved spontaneously, occurred in two patients. Technical difficulty in placing fiducials was noted in 18 patients. Intra-procedural fiducial migration was noted in two patients and only 2/1093 fiducials (.002%) in two esophageal patients migrated as noted on simulation computed tomography scan. Conclusions: EUS-guided fiducial marker placement without fluoroscopy is technically feasible and safe. There were minimal intraprocedure/post-procedure complications. Imaging at the time of simulation also revealed the migration rate to be extremely low. These results may allow for more widespread adoption of EUS-guided fiducial marker placement.
引用
收藏
页码:E378 / E382
页数:5
相关论文
共 22 条
[21]   The use of endoscopic ultrasound-guided gold markers in image-guided radiation therapy of pancreatic cancers: a case series [J].
Varadarajulu, S. ;
Trevino, J. M. ;
Shen, S. ;
Jacob, R. .
ENDOSCOPY, 2010, 42 (05) :423-425
[22]   EUS-guided fiducial placement after radical prostatectomy before targeted radiation therapy for prostate cancer recurrence [J].
Yang, Julie ;
Abdel-Wahab, May ;
Ribeiro, Afonso .
GASTROINTESTINAL ENDOSCOPY, 2011, 73 (06) :1302-1305