Development of a capacitive chemical sensor based on Co(II)-phthalocyanine acrylate-polymer/HfO2/SiO2/Si for detection of perchlorate

被引:11
作者
Braik, M. [1 ,2 ]
Dridi, C. [1 ,2 ,3 ]
Ben Ali, M. [1 ,2 ]
Ali, M. [4 ]
Abbas, M. [4 ]
Zabala, M. [5 ]
Bausells, J. [5 ]
Zine, N. [6 ]
Jaffrezic-Renault, N. [6 ]
Errachid, A. [6 ]
机构
[1] Univ Monastir, LIMA, Fac Sci Monastir, Monastir 5019, Tunisia
[2] Univ Sousse, ISSAT Sousse, Cite Ettafala 4003, Ibn Khaldoun So, Tunisia
[3] Ctr Res Microelect & Nanotcchnol Sousse, Sousse 4034, Tunisia
[4] Natl Res Ctr, Dept Appl Organ Chem, Analyt Lab, Cairo, Egypt
[5] CSIC, IMB, Barcelona 08193, Spain
[6] Univ Lyon 1, ISA, UMR 5280, F-69100 Villeurbanne, France
关键词
D O I
10.5194/jsss-4-17-2015
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report the development of a chemical sensor based on a Co(II) phthalocyanine acrylate polymer (Co(II)Pc-AP) for perchlorate anion detection. We have used two types of transducers, silicon nitride (Si3N4) and hafnium oxide (HfO2). The adhesion of the Co(11)Pc-AP on different transducers and their surface qualities have been studied by contact angle measurements. We haNe studied the pH effect on AllSi/SiO2/HfO2/electrolyte capacitance values for different phosphate buffer solutions (PBS). This optimization step has allowed a sensitivity value of about 44 mV decade-1 towards H+ ions. The fabricated sensors based on Si3N4 and HfO2 transducers functionalized with a Co(11)Pc-AP membrane have been characterized by C(V) measurements for different perchlorate concentrations (from 10-7 to 10-2M). The sensor developed with the HfO2 transducer shows better performances compared to that based on Si3N4: a larger detection range (10(-7) to 10(-2) and 10(-3) to 10(-2) M, respectively) and lower detection limits (10-7 and 10(-3) M). The specificities of our perchlorate sensor have been tested for some interfering ions (nitrate, sulfate and carbonate).
引用
收藏
页码:17 / 23
页数:7
相关论文
共 16 条
  • [1] Abbas M.N., 2011, AM J ANAL CHEM, V2, P820, DOI DOI 10.4236/AJAC.2011.27094
  • [2] Electrical characteristics of metal-insulator-semiconductor structures with atomic layer deposited Al2O3, HfO2, and nanolaminates on different silicon substrates
    Campabadal, F.
    Rafi, J. M.
    Zabala, M.
    Beldarrain, O.
    Faigon, A.
    Castan, H.
    Gomez, A.
    Garcia, H.
    Duenas, S.
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2011, 29 (01):
  • [3] Integrated cell positioning and cell-based ISFET biosensors
    Castellarnau, M.
    Zine, N.
    Bausells, J.
    Madrid, C.
    Juarez, A.
    Samitier, J.
    Errachid, A.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 120 (02) : 615 - 620
  • [4] PREPARATION AND C-V CHARACTERISTICS OF SI-SI3N4 AND SI-SIO2-SI3N4 STRUCTURES
    CHU, TL
    SZEDON, JR
    LEE, CH
    [J]. SOLID-STATE ELECTRONICS, 1967, 10 (09) : 897 - &
  • [5] Cobalt phthalocyanine as a novel molecular recognition reagent for batch and flow injection potentiometric and spectrophotometric determination of anionic surfactants
    El-Nemma, Eman M.
    Badawi, Nahla M.
    Hassan, Saad S. M.
    [J]. TALANTA, 2009, 78 (03) : 723 - 729
  • [6] Physical properties and electrical characteristics of H2O-based and O3-based HfO2 films deposited by ALD
    Fan, Jibin
    Liu, Hongxia
    Kuang, Qianwei
    Gao, Bo
    Ma, Fei
    Hao, Yue
    [J]. MICROELECTRONICS RELIABILITY, 2012, 52 (06) : 1043 - 1049
  • [7] Surface modifications of silicon nitride for cellular biosensor applications
    Gustavsson, Johan
    Altankov, George
    Errachid, Abdelhamid
    Samitier, Josep
    Planell, Josep A.
    Engel, Elisabeth
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (04) : 1839 - 1850
  • [8] pH, pK and pNa detection properties of SiO2/Si3N4 ISFET chemical sensors
    Hajji, B
    Temple-Boyer, P
    Launay, J
    do Conto, T
    Martinez, A
    [J]. MICROELECTRONICS RELIABILITY, 2000, 40 (4-5) : 783 - 786
  • [9] Surface morphology and crystallinity control in the atomic layer deposition (ALD) of hafnium and zirconium oxide thin films
    Hausmann, DM
    Gordon, RG
    [J]. JOURNAL OF CRYSTAL GROWTH, 2003, 249 (1-2) : 251 - 261
  • [10] A fluorescent chemosensor for detection of perchlorate ions in water
    Kumar, Rahul
    Kumar, Sandeep
    Singh, Prabhpreet
    Hundal, Geeta
    Hundal, Maninder Singh
    Kumar, Subodh
    [J]. ANALYST, 2012, 137 (21) : 4913 - 4916