Medical records and radiographs of 16 patients who had anterior decompression, bone grafting, and plating of grade Ill and IV (Allen 1982) unstable cervical spine injuries were reviewed. Surgery was performed within 15 days of injury, reductions were achieved and maintained at follow-up, and fusion occurred in all cases. Neurologic function stabilised or improved in all cases. However, 3 patients (19%) had complications that necessitated additional surgery: one patient with undiagnosed non-contiguous posterior instability, and 2 patients for broken plates. These complications, in retrospect, could have been avoided. © 1990 International Medical Society of Paraplegia.
引用
收藏
页码:564 / 572
页数:9
相关论文
共 24 条
[1]  
Allen B.L., Ferguson R.L., Lehmann T.R., O'Brien R.P., A mechanistic classification of closed, indirect fractures and dislocations of the lower cervical spine, Spine, 7, pp. 1-26, (1982)
[2]  
Bailey R.W., Bradley C.E., Stabilization of the cervical spine by anterior fusion, Journal Ofbone Andjoint Surgery, 42A, pp. 565-594, (1960)
[3]  
Bedbrtok G.M., Pathological principles in the management of spinal cord trauma, Paraplegia, 4, pp. 43-57, (1966)
[4]  
Bohler J., Gaudernale T., Anterior plate stabilization for fracture-dislocations of the lower cervical spine, Journal of Trauma, 20, pp. 203-205, (1980)
[5]  
Bremer A.M., Nguyen T.O., Internal metal plate fixation combined with anterior interbody fusion in cases of cervical spine injury, Neurosurgery, 12, pp. 649-653, (1983)
[6]  
Brown J.A., Havel P., Ebraheim N., Greenblatt S.H., Jackson W.T., Cervical stabilization by plate and bone fusion, Spine, 13, pp. 239-240, (1988)
[7]  
Cabanela M.E., Ebersold M.J., Anterior plate stabilization for bursting teardrop fractures of the cervical spine, Spine, 13, pp. 888-891, (1988)
[8]  
Capen D.A., Garland D.E., Waters R.L., Surgical stabilization of the cervical spine: A comparative analysis of anterior and posterior spine fusions, Clinical Orthopaedics, 196, pp. 229-237, (1985)
[9]  
Caspar W., Anterior cervical fusion and interbody stabilization with the trapezial osteosynthetic plate technique, Aesculap-Wissewscheftliche Informationen Im Selbstverlag Der Aesculap-WerkeAG, D-7200, Tuttlingen, (1984)
[10]  
Cheshire D., The stability of the cervical spine following the conservative treatment of fractures and fracture- dislocations, Paraplegia, 7, pp. 193-203, (1969)