Enhanced conductivity detection of common inorganic anions in electrostatic ion chromatography using water eluent

被引:2
|
作者
Kozaki, Daisuke [1 ]
Shi, Chao-Hong [1 ]
Tanaka, Kazuhiko [1 ,2 ]
Nakatani, Nobutake [3 ]
机构
[1] Hiroshima Univ, Int Dev & Cooperat, Higashihiroshima 7398529, Japan
[2] Tsinghua Univ, Dept Chem, Beijing 100084, Peoples R China
[3] Rakuno Gakuen Univ, Fac Environm Syst, Ebetsu, Hokkaido 0698501, Japan
基金
日本学术振兴会;
关键词
electrostatic ion chromatography; EIC; common anions; conductivity enhancement; water eluent;
D O I
10.3724/SP.J.1123.2011.12049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To enhance the conductivity detection sensitivity of common anions Na-anions in electrostatic ion chromatography EIC by elution with water a conductivity enhancement column packed with strong acid cation exchange resin in the H-form was inserted between an octadecyl silane ODS -silica separation column modified with zwitterionic surfactant CHAPS 3- 3-cholamidopropyl -dimethylammonio propanesulfonate and a conductivity detector. Specifically the Na-anion pairing is converted to H-anion pairing after the EIC separation and then detected sensitively by the conductivity detector. The effects of conductivity enhancement and suppression in the EIC by the enhanced conductivity detection were characterized for the common strong acid anions such as SO4(2)(-) Cl- NO3- I- and CIO4- and weak acid anions such as F- NO2- HCOO- CH3COO- and HCO3-. For the conductivity enhancement effect in the EIC it is found that the conductivity of measured for all strong acid anions Na-anions was enhanced according to the theoretical conductivity predicted for H-anions and that of the measured for weak acid anions was suppressed depending on their pK(a) of H-anions. For the calibration linearity in the EIC the strong acid anions were linear r(2) = 0.99 -1. 00 because the degree of dissociation is almost 1.0 over all the concentration range and that of the weak acid anions was non-linear because the degree of dissociation decreased by increasing the concentration of the weak acid anions. In conclusion the EIC by enhanced conductivity detection was recognized to be useful only for the strong acid anions in terms of conductivity detection and calibration linearity.
引用
收藏
页码:361 / 364
页数:4
相关论文
共 10 条
  • [1] Electrostatic Ion Chromatography of Common Anions and Cations with a Zwitterionic Surfactant-Modified Silica-C18 Column Using Water Eluent
    Masuda, Wakako
    Kozaki, Daisuke
    Nakatani, Nobutake
    Goto, Ryozo
    Mori, Masanobu
    Fugetsu, Bunshi
    Tanaka, Kazuhiko
    BUNSEKI KAGAKU, 2009, 58 (04) : 311 - 315
  • [2] Suppressed electrostatic ion chromatography with tetraborate as eluent and its application to the determination of inorganic anions in snow and rainwater
    Hu, WZ
    Tanaka, K
    Haddad, PR
    Hasebe, K
    JOURNAL OF CHROMATOGRAPHY A, 2000, 884 (1-2) : 161 - 165
  • [3] Determination of monovalent inorganic anions in high-ionic-strength samples by electrostatic ion chromatography with suppressed conductometric detection
    Hu, WZ
    Haddad, PR
    Tanaka, K
    Sato, SJ
    Mori, M
    Xu, Q
    Ikedo, M
    Tanaka, S
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1039 (1-2) : 59 - 62
  • [4] Elucidation of Ion-Pairing Elution Behavior of Anions and Cations in Electrostatic Ion Chromatography Using Water as a Mobile Phase
    Umemura, Tomonari
    CHROMATOGRAPHY, 2019, 40 (03) : 143 - 148
  • [5] Manipulation of separation selectivity of inorganic anions in electrostatic ion chromatography by the use of mixed cationic-zwitterionic micelles as the column coating solution
    Hu, W
    Haddad, PR
    Cook, H
    Yamamoto, H
    Hasebe, K
    Tanaka, K
    Fritz, JS
    JOURNAL OF CHROMATOGRAPHY A, 2001, 920 (1-2) : 95 - 100
  • [7] Determination of common anions in oxalate by ion chromatography coupled with UV photolysis pretreatment
    Cao, Sheng Lin
    Ye, Ming Li
    Lv, Wei De
    Pan, Guang Wen
    Zhang, Ting Ting
    Hu, Zhong Yang
    Liang, Li Na
    Zhu, Yan
    CHINESE CHEMICAL LETTERS, 2012, 23 (11) : 1263 - 1266
  • [8] Water quality monitoring system for determination of ionic nutrients by ion-exclusion chromatography with spectrophotometric detection on cation- and anion-exchange resin columns using water eluent
    Kozaki, Daisuke
    Nakatani, Nobutake
    Mori, Masanobu
    Nakagoshi, Nobukazu
    Tanaka, Kazuhiko
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (07) : 721 - 727
  • [9] Studies on separation of different species containing boron in boric acid solution using electrostatic ion chromatography
    Shen, GJ
    Peng, ZH
    Huang, HY
    Shi, YH
    Yu, AM
    Jin, QH
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1999, 20 (10): : 1538 - 1541
  • [10] Electrostatic ion chromatography of polarizable anions in saline waters with N-{2-[acetyl(3-sulfopropyl)amino]ethyl}-N,N-dimethyldodecanaminium hydroxide (ammonium sulfobetaine-1) as the stationary phase and a dilute electrolytic solution as the mobile phase
    Hu, WZ
    Hasebe, K
    Tanaka, K
    Haddad, PR
    JOURNAL OF CHROMATOGRAPHY A, 1999, 850 (1-2) : 161 - 166