摘要
Despite many innovations and developments in the field of fiber-optic chemical sensors, optical fibers have not been employed to both view a sample and concurrently detect an analyte of interest. While chemical sensors employing a single optical fiber or a noncoherent fiber-optic bundle have been applied to a wide variety of analytical determinations, they cannot be used for imaging. Similarly, coherent imaging fibers have been employed only for their originally intended purpose, image transmission. We herein report a new technique for viewing a sample and measuring surface chemical concentrations that employs a coherent imaging fiber. The method is based on the deposition of a thin, analyte-sensitive polymer layer on the distal surface of a 350-mu m-diameter imaging fiber. We present results from a pH sensor array and an acetylcholine biosensor array, each of which contains similar to 6000 optical sensors. The acetylcholine biosensor has a detection limit of 35 mu M and a fast (<1 s) response time. In association with an epifluorescence microscope and a charge-coupled device, these modified imaging fibers can display visual information of a remote sample with 4-mu m spatial resolution, allowing for alternating acquisition of both chemical analysis and visual histology.
引用
收藏
页码:2750 / 2757
页数:8
相关论文
共 32 条
[1]  
[Anonymous], [No title captured]
[2]   FIBEROPTIC CHEMICAL SENSORS [J].
ARNOLD, MA .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :A1015-A1025
[3]   RECENT ADVANCES IN THE DEVELOPMENT AND ANALYTICAL APPLICATIONS OF BIOSENSING PROBES [J].
ARNOLD, MA ;
MEYERHOFF, ME .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1988, 20 (03) :149-196
[4]  
BRIGHT GR, 1993, OPTICAL MICROSCOPY E, P87
[5]   FABRICATION OF PATTERNED SENSOR ARRAYS WITH ARYL AZIDES ON A POLYMER-COATED IMAGING OPTICAL-FIBER BUNDLE [J].
BRONK, KS ;
WALT, DR .
ANALYTICAL CHEMISTRY, 1994, 66 (20) :3519-3520
[6]  
Chigusa Y, 1986, OPTOELECTRON DEVICES, V1, P203
[7]  
CONLON HD, 1986, J CHEM EDUC, V63, P368
[8]   FLUORESCEIN LABELING OF FAB WHILE PRESERVING SINGLE THIOL [J].
DERBALIAN, GP ;
KAMEDA, N ;
ROWLEY, GL .
ANALYTICAL BIOCHEMISTRY, 1988, 173 (01) :59-63
[9]   ANALYTICAL-CHEMISTRY IN MICROENVIRONMENTS - SINGLE NERVE-CELLS [J].
EWING, AG ;
STREIN, TG ;
LAU, YY .
ACCOUNTS OF CHEMICAL RESEARCH, 1992, 25 (10) :440-447
[10]   AMPEROMETRIC SENSORS FOR PEROXIDE, CHOLINE, AND ACETYLCHOLINE BASED ON ELECTRON-TRANSFER BETWEEN HORSERADISH-PEROXIDASE AND A REDOX POLYMER [J].
GARGUILO, MG ;
HUYNH, N ;
PROCTOR, A ;
MICHAEL, AC .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :523-528