LINE-SHAPE STUDIES FOR SINGLE-PASS AND TRIPLE-PASS FABRY-PEROT-INTERFEROMETER SYSTEMS

被引:6
|
作者
PALIK, ED
BOUKARI, H
GAMMON, RW
机构
[1] Institute for Physical Science and Technology, University of Maryland, College Park, MD
来源
APPLIED OPTICS | 1995年 / 34卷 / 01期
关键词
FABRY-PEROT INTERFEROMETER; MULTIPASSING; LINE SHAPE; PINHOLE EFFECT;
D O I
10.1364/AO.34.000058
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To test the model developed in the preceding paper [Appl. Opt. 34, this issue (1994)] regarding the line shape produced by a Fabry-Perot interferometer system in a multipass mode, we have used three Lorentzian line shapes formed in scattering processes and subjected them to single and triple passes with some variation in the pinhole diameter. In most cases we find good agreement with the calculations with the only adjustable parameter being the single-pass contrast C-1. Where differences occur, plausible explanations are offered.
引用
收藏
页码:58 / 68
页数:11
相关论文
共 12 条
  • [1] Tandem triple-pass Fabry-Perot interferometer for applications in the near infrared
    Gehrsitz, S
    Sigg, H
    Siegwart, H
    Krieger, M
    Heine, C
    Morf, R
    Reinhart, FK
    Martin, W
    Rudigier, H
    APPLIED OPTICS, 1997, 36 (22): : 5355 - 5361
  • [2] CONSTRUCTION AND PERFORMANCE OF A BRILLOUIN-SCATTERING SET-UP USING A TRIPLE-PASS TANDEM FABRY-PEROT-INTERFEROMETER
    MOCK, R
    HILLEBRANDS, B
    SANDERCOCK, R
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (06): : 656 - 659
  • [3] Automated stabilization of a single-pass plane Fabry-Perot interferometer
    Departamento de Física, Univ. Fed. do Espírito Santo, 29060-900 Vitória ES, Brazil
    不详
    不详
    Appl. Opt., 27 (6707-6710):
  • [4] Automated stabilization of a single-pass plane Fabry-Perot interferometer
    Suave, RN
    deCastro, ARB
    APPLIED OPTICS, 1997, 36 (27): : 6707 - 6710
  • [5] SIMPLE DOUBLE-PASS SPHERICAL FABRY-PEROT-INTERFEROMETER
    CANNELL, DS
    DUBIN, SB
    LUNACEK, JH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1973, 44 (11): : 1651 - 1653
  • [6] PRESSURE-SCANNED 3-PASS FABRY-PEROT-INTERFEROMETER
    DURVASULA, LN
    GAMMON, RW
    APPLIED OPTICS, 1978, 17 (20): : 3298 - 3303
  • [7] SPECTROMETER WITH A 2-PASS FABRY-PEROT-INTERFEROMETER AND PHOTOELECTRIC DIGITAL SPECTRAL RESOLUTION
    KRIVOKHIZHA, SV
    NIYAZOV, OA
    SHVETS, EV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1980, 23 (06) : 1463 - 1465
  • [8] CONSTRUCTION AND PERFORMANCE OF A BRILLOUIN SCATTERING SET-UP USING A TRIPLE-PASS TANDEM FABRY-PEROT INTERFEROMETER.
    Mock, R.
    Hillebrands, B.
    Sandercock, R.
    1600, (20):
  • [9] Breaking the Contrast Limit in Single-Pass Fabry-Perot Spectrometers
    Antonacci, G.
    De Panfilis, S.
    Di Domenico, G.
    Delre, E.
    Ruocco, G.
    PHYSICAL REVIEW APPLIED, 2016, 6 (05):
  • [10] FABRY-PEROT LINE-SHAPE STUDIES OF KDP SOFT MODE
    DURVASULA, LN
    GAMMON, RW
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1977, 67 (10) : 1410 - 1410