CONFOCAL SCANNING MICROFLUOROMETRY OF DUAL-LABELED SPECIMENS USING 2 EXCITATION WAVELENGTHS AND LOCK-IN DETECTION TECHNIQUE

被引:21
作者
ASLUND, N [1 ]
CARLSSON, K [1 ]
机构
[1] ROYAL INST TECHNOL,S-10044 STOCKHOLM 70,SWEDEN
关键词
CONFOCAL MICROSCOPY; MICROFLUOROMETRY; DUAL LABELING; LOCK-IN DETECTION; INTENSITY MODULATION;
D O I
10.1016/0968-4328(93)90038-3
中图分类号
TH742 [显微镜];
学科分类号
摘要
A new technique for simultaneous recording of multiple fluorophores has been implemented in a confocal scanning laser microscope. Dual excitation wavelengths, intensity-modulated at different frequencies and two lock-in amplifiers tuned to the corresponding frequencies are used. In this way two fluorophores can be independently, albeit simultaneously, excited. This technique, Intensity-modulated Multiple-beam Scanning (IMS) microfluorometry, has the potential to virtually eliminate the cross-talk between fluorophores that often occurs when recording multiple-labelled specimens. Furthermore, it will offer simultaneous information about both the excitation and emission spectra of the fluorophores used. Also, variations in decay time over the image area can be studied independently and simultaneously for two fluorophores.
引用
收藏
页码:603 / 609
页数:7
相关论文
共 13 条
[1]  
[Anonymous], 1993, NEUROPROTOCOLS
[2]   FLUORESCENCE LIFETIME IMAGING USING A CONFOCAL LASER SCANNING MICROSCOPE [J].
BUURMAN, EP ;
SANDERS, R ;
DRAAIJER, A ;
GERRITSEN, HC ;
VANVEEN, JJF ;
HOUPT, PM ;
LEVINE, YK .
SCANNING, 1992, 14 (03) :155-159
[3]   A CONFOCAL LASER MICROSCOPE SCANNER FOR DIGITAL RECORDING OF OPTICAL SERIAL SECTIONS [J].
CARLSSON, K ;
LILJEBORG, A .
JOURNAL OF MICROSCOPY-OXFORD, 1989, 153 :171-180
[4]   REDUCTION OF CROSS-TALK BETWEEN FLUORESCENT LABELS IN SCANNING LASER MICROSCOPY [J].
CARLSSON, K ;
MOSSBERG, K .
JOURNAL OF MICROSCOPY-OXFORD, 1992, 167 :23-37
[6]  
Lakowicz J. R., 2010, PRINCIPLES FLUORESCE
[7]   LIFETIME-SELECTIVE FLUORESCENCE IMAGING USING AN RF PHASE-SENSITIVE CAMERA [J].
LAKOWICZ, JR ;
BERNDT, KW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (07) :1727-1734
[8]   PROSPECTS FOR CONFOCAL IMAGING BASED ON NANOSECOND FLUORESCENCE DECAY TIME [J].
MORGAN, CG ;
MITCHELL, AC ;
MURRAY, JG .
JOURNAL OF MICROSCOPY, 1992, 165 :49-60
[9]   A PHASE QUADRATURE CORRELATOR FOR THE MEASUREMENT OF FLUORESCENCE-DECAY TIMES BY SINGLE-PHOTON COUNTING [J].
MORGAN, CG ;
MURRAY, JG .
CHEMICAL PHYSICS LETTERS, 1991, 179 (03) :211-217
[10]   DETECTION OF DOUBLY STAINED FLUORESCENT SPECIMENS USING CONFOCAL MICROSCOPY [J].
MOSSBERG, K ;
ERICSSON, M .
JOURNAL OF MICROSCOPY, 1990, 158 :215-224