METHICILLIN-RESISTANT STAPHYLOCOCCUS-AUREUS - OPTIMIZATION OF THE AGAR SCREEN PLATE METHOD

被引:5
作者
ALFA, MJ [1 ]
ONGSANSOY, E [1 ]
HOBAN, S [1 ]
MATHEW, T [1 ]
GREENAWAY, C [1 ]
机构
[1] UNIV MANITOBA,DEPT MED MICROBIOL,WINNIPEG,MB,CANADA
关键词
D O I
10.1016/0732-8893(94)90077-9
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Swab inoculation of oxacillin agar screen plates was compared with drop inoculation for detection of methicillin-resistant Staphylococcus aureus. The poor sensitivity of the swab method (59%) was related to heteroresistance of the S. aureus isolates. We recommend the drop method (100% sensitivity) because interpretation of results was significantly easier, making it more reliable.
引用
收藏
页码:121 / 124
页数:4
相关论文
共 13 条
[1]  
CHAMBERS H F, 1988, Clinical Microbiology Reviews, V1, P173
[2]   EVALUATION OF LABORATORY TESTS FOR DETECTION OF METHICILLIN-RESISTANT STAPHYLOCOCCUS-AUREUS AND STAPHYLOCOCCUS-EPIDERMIDIS [J].
COUDRON, PE ;
JONES, DL ;
DALTON, HP ;
ARCHER, GL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 24 (05) :764-769
[3]   A PROBE FOR THE DETECTION OF METHICILLIN-RESISTANT STAPHYLOCOCCUS-AUREUS [J].
FLUIT, AC ;
BOX, ATA ;
VERHOEF, J .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1990, 9 (08) :605-608
[4]   EXPRESSION OF METHICILLIN RESISTANCE IN HETEROGENEOUS STRAINS OF STAPHYLOCOCCUS-AUREUS [J].
HARTMAN, BJ ;
TOMASZ, A .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1986, 29 (01) :85-92
[5]   EFFECT OF SOURCE OF MUELLER-HINTON AGAR ON DETECTION OF OXACILLIN RESISTANCE IN STAPHYLOCOCCUS-AUREUS USING A SCREENING METHODOLOGY [J].
HINDLER, JA ;
WARNER, NL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (04) :734-735
[6]   IMPLICATIONS OF ACQUIRED OXACILLIN RESISTANCE IN THE MANAGEMENT AND CONTROL OF STAPHYLOCOCCUS-AUREUS INFECTIONS [J].
MASSANARI, RM ;
PFALLER, MA ;
WAKEFIELD, DS ;
HAMMONS, GT ;
MCNUTT, LA ;
WOOLSON, RF ;
HELMS, CM .
JOURNAL OF INFECTIOUS DISEASES, 1988, 158 (04) :702-709
[7]   NEW RECOMMENDATIONS FOR DISK DIFFUSION ANTIMICROBIAL SUSCEPTIBILITY TESTS FOR METHICILLIN-RESISTANT (HETERORESISTANT) STAPHYLOCOCCI [J].
MCDOUGAL, LK ;
THORNSBERRY, C .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 19 (04) :482-488
[8]   COMPARISON OF TEST SYSTEMS FOR RECOGNITION OF METHICILLIN RESISTANCE IN STAPHYLOCOCCUS-AUREUS [J].
MOUTON, RP ;
MULDERS, SLT ;
DEKNIJFF, J ;
HERMANS, J .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1989, 8 (11) :968-973
[9]   EVALUATION OF COMMERCIAL AND STANDARD METHODOLOGY FOR DETERMINATION OF OXACILLIN SUSCEPTIBILITY IN STAPHYLOCOCCUS-AUREUS [J].
SKULNICK, M ;
SIMOR, AE ;
GREGSON, D ;
PATEL, M ;
SMALL, GW ;
KREISWIRTH, B ;
HATHOWAY, D ;
LOW, DE .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (08) :1985-1988
[10]   COMPARATIVE-EVALUATION OF THE MRS TEST - A 4 TO 6 HOUR SCREENING-TEST FOR DETECTING OXACILLIN-RESISTANT STAPHYLOCOCCI [J].
WELLSTOOD, S .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1989, 12 (05) :395-399