PROSPECTIVE COMPARISON OF T2-WEIGHTED FAST SPIN-ECHO, WITH AND WITHOUT FAT-SUPPRESSION, AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES IN THE UPPER ABDOMEN

被引:87
|
作者
SCHWARTZ, LH [1 ]
SELTZER, SE [1 ]
TEMPANY, CMC [1 ]
SILVERMAN, SG [1 ]
PIWNICAWORMS, DR [1 ]
ADAMS, DF [1 ]
HERMAN, L [1 ]
HERMAN, LT [1 ]
HOOSHMAND, R [1 ]
机构
[1] HARVARD UNIV,BRIGHAM & WOMENS HOSP,SCH MED,DEPT RADIOL,BOSTON,MA 02115
关键词
LIVER NEOPLASMS; MAGNETIC RESONANCE (MR); PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1148/radiology.189.2.8210368
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate use of fast spin-echo (FSE) magnetic resonance imaging with and without fat suppression in the liver and upper abdomen. MATERIALS AND METHODS: Conventional spin-echo (SE) T2-weighted, FSE T2-weighted, and fat-suppressed FSE T2-weighted images from 37 patients strongly suspected to have focal hepatic lesions were evaluated. RESULTS: Quantitative analysis demonstrated that fat-suppressed FSE imaging had the highest lesion-liver contrast-to-noise ratio; conventional SE imaging, the lowest. In a qualitative analysis, FSE imaging was preferred. In a rank order analysis, FSE imaging was preferred 83% of the time and fat-suppressed FSE imaging 17% of the time as regards overall image quality; fat-suppressed FSE imaging was preferred 64% of the time, FSE imaging 23% of the time, and conventional SE imaging 13% of the time as regards signal abnormality detection. CONCLUSION: FSE imaging with and without fat suppression is a potentially useful pulse sequence for evaluating the upper abdomen.
引用
收藏
页码:411 / 416
页数:6
相关论文
共 50 条
  • [41] Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging
    Gaa, J
    Hatabu, H
    Jenkins, RL
    Finn, JP
    Edelman, RR
    RADIOLOGY, 1996, 200 (02) : 459 - 464
  • [42] WHY FAT IS BRIGHT IN RARE AND FAST SPIN-ECHO IMAGING
    HENKELMAN, RM
    HARDY, PA
    BISHOP, JE
    POON, CS
    PLEWES, DB
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05): : 533 - 540
  • [44] UNSUPPRESSED FAT IN THE RIGHT ANTERIOR DIAPHRAGMATIC REGION ON FAT-SUPPRESSED T2-WEIGHTED FAST SPIN-ECHO MR-IMAGES
    YOSHIMITSU, K
    VARMA, DGK
    JACKSON, EF
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02): : 145 - 149
  • [45] Comparison of fast turbo-spin-echo and gradient-and-spin-echo sequences as well as echo planar imaging with conventional spin-echo sequences in MRI of focal liver lesions at 1.0 tesla.
    Jung, G
    Krahe, T
    Kugel, H
    Gieseke, J
    Walter, C
    Fischbach, R
    Landwehr, P
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (02): : 137 - 143
  • [46] FAST SPIN-ECHO MR-IMAGING OF THE ABDOMEN - CONTRAST OPTIMIZATION AND ARTIFACT REDUCTION
    LOW, RN
    HINKS, RS
    ALZATE, GD
    SHIMAKAWA, A
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 637 - 645
  • [47] DIFFUSION-WEIGHTED MR MICROSCOPY WITH FAST SPIN-ECHO
    BEAULIEU, CF
    ZHOU, XH
    COFER, GP
    JOHNSON, GA
    MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 201 - 206
  • [48] MR of focal liver lesions: Comparison of breath-hold and non-breath-hold hybrid RARE and conventional spin-echo T2-weighted pulse sequences
    Carpenter, KD
    Macaulay, SE
    Schulte, SJ
    Obregon, RG
    Nelson, RC
    Simon, HE
    Schmiedl, UP
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 596 - 602
  • [49] MRI in neuro-Behcet's syndrome:: comparison of conventional spin-echo and FLAIR pulse sequences
    Jäger, HR
    Albrecht, T
    Curati-Alasonatti, WL
    Williams, EJ
    Haskard, DO
    NEURORADIOLOGY, 1999, 41 (10) : 750 - 758
  • [50] CARDIAC ABNORMALITIES - ASSESSMENT WITH T2-WEIGHTED TURBO SPIN-ECHO MR-IMAGING WITH ELECTROCARDIOGRAM GATING AT 0.5 T
    SEELOS, KC
    VONSMEKAL, A
    VAHLENSIECK, M
    GIESEKE, J
    REISER, M
    RADIOLOGY, 1993, 189 (02) : 517 - 522