PROSPECTIVE COMPARISON OF T2-WEIGHTED FAST SPIN-ECHO, WITH AND WITHOUT FAT-SUPPRESSION, AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES IN THE UPPER ABDOMEN

被引:87
|
作者
SCHWARTZ, LH [1 ]
SELTZER, SE [1 ]
TEMPANY, CMC [1 ]
SILVERMAN, SG [1 ]
PIWNICAWORMS, DR [1 ]
ADAMS, DF [1 ]
HERMAN, L [1 ]
HERMAN, LT [1 ]
HOOSHMAND, R [1 ]
机构
[1] HARVARD UNIV,BRIGHAM & WOMENS HOSP,SCH MED,DEPT RADIOL,BOSTON,MA 02115
关键词
LIVER NEOPLASMS; MAGNETIC RESONANCE (MR); PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1148/radiology.189.2.8210368
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate use of fast spin-echo (FSE) magnetic resonance imaging with and without fat suppression in the liver and upper abdomen. MATERIALS AND METHODS: Conventional spin-echo (SE) T2-weighted, FSE T2-weighted, and fat-suppressed FSE T2-weighted images from 37 patients strongly suspected to have focal hepatic lesions were evaluated. RESULTS: Quantitative analysis demonstrated that fat-suppressed FSE imaging had the highest lesion-liver contrast-to-noise ratio; conventional SE imaging, the lowest. In a qualitative analysis, FSE imaging was preferred. In a rank order analysis, FSE imaging was preferred 83% of the time and fat-suppressed FSE imaging 17% of the time as regards overall image quality; fat-suppressed FSE imaging was preferred 64% of the time, FSE imaging 23% of the time, and conventional SE imaging 13% of the time as regards signal abnormality detection. CONCLUSION: FSE imaging with and without fat suppression is a potentially useful pulse sequence for evaluating the upper abdomen.
引用
收藏
页码:411 / 416
页数:6
相关论文
共 50 条
  • [1] Fat-suppressed T2-weighted MR imaging of hepatocellular carcinoma and metastases: Comparison of conventional spin-echo, fast spin-echo, and echoplanar pulse sequences
    Kanematsu, M
    Hoshi, H
    Murakami, T
    Itoh, K
    Hori, M
    Inaba, Y
    Kondo, H
    Yokoyama, R
    Nakamura, H
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (01): : 25 - 32
  • [2] COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS
    RYDBERG, JN
    LOMAS, DJ
    COAKLEY, KJ
    HOUGH, DM
    EHMAN, RL
    RIEDERER, SJ
    RADIOLOGY, 1995, 194 (02) : 431 - 437
  • [3] COMPARISON OF T2-WEIGHTED SPIN-ECHO AND FAST SPIN-ECHO TECHNIQUES IN THE EVALUATION OF MYELINATION
    PRENGER, EC
    BECKETT, WW
    KOLLIAS, SS
    BALL, WS
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02): : 179 - 184
  • [4] Focal liver lesions: Characterization with conventional spin-echo versus fast spin-echo T2-weighted MR imaging
    Schima, W
    Saini, S
    Echeverri, JA
    Hahn, PF
    Harisinghani, M
    Mueller, PR
    RADIOLOGY, 1997, 202 (02) : 389 - 393
  • [5] Liver T2-weighted MR imaging: Comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences
    Tang, Y
    Yamashita, Y
    Namimoto, T
    Abe, Y
    Takahashi, M
    RADIOLOGY, 1997, 203 (03) : 766 - 772
  • [6] INTRACEREBRAL LESION CONTRAST WITH SPIN-ECHO AND FAST SPIN-ECHO PULSE SEQUENCES
    NORBASH, AM
    GLOVER, GH
    ENZMANN, DR
    RADIOLOGY, 1992, 185 (03) : 661 - 665
  • [7] Differentiation between hepatic cavernous hemangioma and malignant tumor with T2-weighted MRI: Comparison of fast spin-echo and breathhold fast spin-echo pulse sequences
    Soyer, P
    Dufresne, AC
    Somveille, E
    Lenormand, S
    Scherrer, A
    Rymer, R
    CLINICAL IMAGING, 1998, 22 (03) : 200 - 210
  • [8] T2-WEIGHTED MR-IMAGING OF THE CHEST - COMPARISON OF ELECTROCARDIOGRAPH-TRIGGERED CONVENTIONAL AND TURBO SPIN-ECHO AND NONTRIGGERED TURBO SPIN-ECHO SEQUENCES
    HADDAD, JL
    ROFSKY, NM
    AMBROSINO, MM
    NAIDICH, DP
    WEINREB, JC
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 325 - 329
  • [9] T2-weighted MRI of rectosigmoid carcinoma: Comparison of respiratory-triggered fast spin-echo, breathhold fast-recovery fast spin-echo, and breathhold single-shot fast spin-echo sequences
    Yamashita, Shuhei
    Masui, Takayuki
    Katayama, Motoyuki
    Sato, Kimihiko
    Yoshizawa, Nobuko
    Seo, Hidekazu
    Sakahara, Harumi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 511 - 516
  • [10] MRI of the intracerebral lesions at 0.5 tesla: Comparison of fast spin-echo and conventional spin-echo sequences
    Incesu, L
    Gunes, M
    Akan, H
    Selcuk, MB
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1996, 20 (02) : 105 - 113