MR Imaging-Guided Partial Volume Correction of PET Data in PET/MR Imaging

被引:33
|
作者
Erlandsson, Kjell [1 ]
Dickson, John [2 ]
Arridge, Simon [3 ]
Atkinson, David [4 ]
Ourselin, Sebastien [5 ]
Hutton, Brian F. [1 ,6 ]
机构
[1] UCLH, Univ Coll London, Inst Nucl Med, Euston Rd T-5, London NW1 2BU, England
[2] Univ Coll London Hosp, Inst Nucl Med, Euston Rd T-5, London NW1 2BU, England
[3] UCL, Dept Comp Sci, Gower St, London WC1E 6BT, England
[4] UCL, Ctr Med Imaging, 250 Euston Rd, London NW1 2PG, England
[5] UCL, Ctr Med Imaging Comp, Gower St, London WC1E 6BT, England
[6] Univ Wollongong, Ctr Med Radiat Phys, Northfields Ave, Wollongong, NSW 2522, Australia
基金
英国工程与自然科学研究理事会;
关键词
Partial volume effects; Partial volume correction; PET/MR imaging; Quantification;
D O I
10.1016/j.cpet.2015.09.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Partial volume effects are caused by the limited spatial resolution of the PET system. There is increasing evidence that partial volume correction (PVC) is necessary to guarantee quantitative accuracy in PET; however, there is reluctance to apply PVC routinely in clinical practice, partly because of uncertainty regarding the method of choice. To perform accurate PVC, it is necessary to introduce information from high-resolution anatomic images, such as MR imaging. All the methods rely on accurate coregistration between the anatomic image and the PET image. PET/MR imaging offers clear advantages for PVC and can help alleviate the image registration issues.
引用
收藏
页码:161 / +
页数:18
相关论文
共 50 条
  • [21] PET/MR Imaging in Cardiovascular Imaging
    Rischpler, Christoph
    Woodard, Pamela K.
    PET CLINICS, 2019, 14 (02) : 233 - +
  • [22] Hybrid MR-guided and PET-guided motion correction of PET images in simultaneous PET/MR
    Feng, Tao
    Ahlman, Mark
    Tsui, Benjamin
    Guo, Liheng
    Guttman, Mike
    McVeigh, Elliot
    Bluemke, David
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [23] Motion correction for PET data using subspace-based real-time MR imaging in simultaneous PET/MR
    Marin, Thibault
    Djebra, Yanis
    Han, Paul K.
    Chemli, Yanis
    Bloch, Isabelle
    El Fakhri, Georges
    Ouyang, Jinsong
    Petibon, Yoann
    Ma, Chao
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23):
  • [24] A hybrid method for generation of attenuation map for MR-based attenuation correction of PET data in prostate PET/MR imaging
    Mehdi Shirin Shandiz
    Mohammad Hadi Arabi
    Pardis Ghafarian
    Mehrdad Bakhshayesh Karam
    Hamidreza Saligheh Rad
    Mohammad Reza Ay
    EJNMMI Physics, 1 (Suppl 1)
  • [25] Nanoprobes for PET/MR Imaging
    Liu, Huanhuan
    Wang, Runze
    Gao, Haiyan
    Chen, Lijuan
    Li, Xiaochen
    Yu, Xuan
    Wu, Yaping
    Bai, Yan
    Wei, Wei
    Wang, Meiyun
    ADVANCED THERAPEUTICS, 2024, 7 (02)
  • [26] PET/MR hybrid imaging
    Quick, Harald H.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (04): : 269 - 270
  • [27] Hybrid imaging with PET/CT and PET/MR
    Andreas Kjaer
    Cancer Imaging, 14 (Suppl 1)
  • [28] Breast PET/MR imaging
    Melsaether, Amy
    Moy, Linda
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2017, 55 (03) : 579 - +
  • [29] Simultaneous PET and MR imaging
    Shao, YP
    Cherry, SR
    Farahani, K
    Meadors, K
    Siegel, S
    Silverman, RW
    Marsden, PK
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (10): : 1965 - 1970
  • [30] PET/MR Imaging of the Pancreas
    Mallak, Nadine
    Hope, Thomas A.
    Guimaraes, Alexander R.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2018, 26 (03) : 345 - +